NOTE:
1.
Detection Range: 50 – 600 V
Frequency Response: 50/60 Hz
2.
The left top corner of the meter (marked "EF" at the rear of the
meter) is the optimum position of the meter for non-contact AC
voltage detections.
3.
The meter's electric field intensity indication is affected by the
magnitude of the AC voltage of the conductor under test, the
distance between the meter and the conductor, the insulation of
the conductor, etc.
4.
Because of the meter's detection limit, a line (or conductor)
under test may be live even if the meter does not indicate the
presence of electric field.
5.
Before use, verify the meter's operation by detecting a known
AC voltage.
6.
To avoid electric shock, do not touch any conductor with hand or
skin.
AC VOLTAGE MEASUREMENT FUNCTION
In Auto Check mode, press the "SELECT" key three times to select
AC voltage measurement function. The display will show the symbol
" " and voltage measurement unit.
Connect the test leads across the source or circuit to be tested. Read
the voltage reading on the display.