Best WC43I80 Manuel D'instructions page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NON-DUCTED INSTALLATION ONLY
10. Install blade guard. Align tabs of the
guard with slots on top of the hood.
Fig. 14.
11. From inside the hood, bend tabs over
to secure the blade guard to the hood.
12. Plug power cord into 120 VAC
receptacle. Fig. 15.
13. Coil and tape remaining power cord
to the top of the range hood.
14. Install two charcoal filters onto the
blower. Fig. 16.
15. Re-install grease filter. Fig. 17.
16. Close the glass front panel.
DUCTED INSTALLATION ONLY
P u r c h a s e F l u e K i t M o d e l
AEWC43SP from your local dealer.
Purchase 6" round metal duct, metal
elbows, wall cap or roof cap as
required.
Purchase aluminum duct tape.
17. Center mounting bracket directly
over range hood. Fig. 18.
18. Secure bracket to wall using (2)
4.8 x 38 mm mounting screws and
drywall anchors (provided).
19. Press discharge collar / damper into
blower duct connector. Fig. 19.
20. Install an appropriate wall or roof
cap, with damper, to exhaust air to
the outside. Run 6" round metal duct
to the outside location.
21. Tape all duct joints with aluminum
duct tape.
All manuals and user guides at all-guides.com
FIG.16
- 11 -
TAPE
DRYWALL
ANCHORS
MOUNTING
BRACKET
4.8 x 38 mm
SCREWS
DISCHARGE
COLLAR
TABS
FIG.14
FIG.15
FIG.17
CENTERLINE
OF HOOD
FIG.18
6"
ROUND
DUCT
FIG.19

Publicité

Table des Matières
loading

Table des Matières