ENGLISH
6) Inputs state optical signals
During the normal operation of the equipment, the display shows the inputs state in the following way:
FOT - Photocell
The segment of the display goes off when the photocell is covered by the passage of people or cars.
FTS - Photostop
The segment of the display goes off when the optic barrier is covered by the passage of people or cars.
START - Common Start
The segment of the display goes on at the Start command.
PED - Pedestrian Start
The segment of the display goes on at the command of Pedestrian Start.
FC1A - Motor 1 opening limit switch
The segment of the display goes off when the limit switch is enabled.
FC1C - Motor 1 closing limit switch
The segment of the display goes off when the limit switch is enabled.
FC2A - Motor 2 opening limit switch
The segment of the display goes off when the limit switch is enabled.
FC2C - Motor 2 closing limit switch
The segment of the display goes off when the limit switch is enabled.
7) Definitions of Trimmers
RV1 – Slow-down speed and power regulation
It regulates the power supplied to the motors during the operation except at the departure (100% of torque) and during the slowing-down minimum
speed. Rotate the trimmer in clockwise sense to increase the power supplied to the motors. During the programming phase, it regulates the slowing-
down speed of the gate. The regulation of the slowing-down speed is not linear but in jerky way (Total 4). Rotate the trimmer in clockwise sense to
increase the slowing-down speed.
28