IMPORTANT INSTRUCTIONS -
Models: ES80S, ES130S,
ES80D, ES130D
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
A210572218 Rev. i 8-12
All manuals and user guides at all-guides.com
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
h) Suitable for use with electronic speed control device.
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING:
i) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY. DO NOT
DO NOT USE IN KITCHENS.
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour Air King ES80S

  • Page 1 All manuals and user guides at all-guides.com IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: ES80S, ES130S, Exhaust Fan ES80D, ES130D READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan 1. Unpack fan from the carton and confirm that all pieces are present. In Joist addition to the exhaust fan you should have: 1 - Grill...
  • Page 3: Completing The Installation

    3a. Continuous Ventilation: For two speed fans wired for continuous ventilation, connect the White wire of the fan to the White (Neutral) 2a. SINGE SPEED UNITS (models ES80S and ES130S): Plug the fan’s 2 wire from the power source. Connect the ground wire from the house pin quick connect motor cord into the receptacle located on the side of to the green wire from the fan housing.
  • Page 4: Troubleshooting Guide

    All manuals and user guides at all-guides.com NOTE: If the housing is mounted to far or not far enough into the ceiling for the flange to make a solid connection, loosen the mounting channel and adjust the housing up or down on the rails. Once in place, fully tighten the mounting channel nuts.
  • Page 5: Customer Service

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6: Replacement Parts Diagram

    5S1239009 #10 Ground Screw 5S1999002 Mounting Rails 5S1299002 14 ga Ground Wire 5S1999003 Blower Assembly 5S2239008 Wire Compartment Assembly - ES80S 5S1239001 6” Metal Collar Assembly 5S5299100 Wire Compartment Assembly - ES130S 5S1239002 Screws 5S1999010 Wire Compartment Assembly - ES80D...
  • Page 7: Ventilateur D'évacuation

    All manuals and user guides at all-guides.com INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modéles : ES80S, ES130S, Ventilateur d’Évacuation ES80D, ES130D LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 8: Nouvelle Construction

    All manuals and user guides at all-guides.com INSTRUCTIONS D’INSTALLATION AVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation du Ventilateur d’évacuation Solive 1. Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes.
  • Page 9 (neutre) blanc de la source d’alimentation. Reliez le fil de 2a. UNITÉS À UNE VITESSE (modéles ES80S et ES130S) : Branchez terre de la maison au fil vert du boîtier du ventilateur. Reliez 2 fils la corde à...
  • Page 10: Guide De Dépannage

    All manuals and user guides at all-guides.com REMARQUE : Si le boîtier est monté très loin ou pas assez loin dans le plafond pour pouvoir fixer solidement la bride, desserrez le canal de montage et ajustez le boîtier vers le haut ou vers le bas sur les rails. Une fois en place, serrez les écrous de montage du canal.
  • Page 11: Garantie Limitée

    Cette garantie ne couvre pas les coûts d’expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d’expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 12: Diagramme Des Pièces De Remplacement

    Fil de mise à la terre de calibre # 14 5S1999003 Assemblée de la Soufflante 5S2239008 Assemblée du compartiment du fil - ES80S 5S1239001 Assemblée de collier en métal de 6 po 5S5299100 Assemblée du compartiment du fil - ES130S...