TROUBLE SHOOTING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
COMPONENT TESTING PROCEDURES
Component Electrical Testing (with ohmmeter)
Thermistor resistance 10K Ω @ 25°C (77°F)
Thermostat 1 resistance < 1Ω
Thermostat 3 resistance < 1Ω
- If resistance is infinity, replace thermostat 3.
Thermostat 2 resistance < 1Ω
- If resistance is infinity, replace thermostat 2.
Heater resistance 10 Ω
- If resistance is infinity, replace Heate
Measure resistance of the following terminal
1) Door switch : open
Terminal : "COM" - "NC" (1-3) < 1Ω
Terminal : "COM" - "NO" (1-2) : ∞ Ω
2) Door switch push: On
Terminal : "COM" - "NC" (1-3) : ∞ Ω
Terminal : "COM" - "NO" (1-2) < 1Ω
Technical_information-02835F_EN.indd 8
All manuals and user guides at all-guides.com
WARNING
Centrifugal Switch (Motor)
8
Belt Cut-off S/W
- Lever open: Resistance value < 1Ω
- Lever push: Resistance value : ∞ Ω
Lamp resistance 80~100 Ω (Violet & gray)
Motor (Electronic & GAS)
Contacts
Function
1M
2M
Start
Run
= Contact closed
3M
5M
6M
2.88Ω between