6
• To check the correct capacity, REFCO recommends using the REF-METER-OCTA filling
scale.
• After reaching the filling quantity, close the valves of the assembly aid.
• Disconnect all hoses from the system
• Open valves (6+7)
Service of manifold
The charging hoses must be checked and clean of oil residue before each use. A visible
control is also necessary to
ensure that the hoses and the connection are undamaged and tight.
The seals of a manifold are naturally subject to a mechanical and age-related wear. There-
fore, the fitter is regularly on the user to check for leaks.
If the valves are leaking, replace the entire valve core.
m After changing spare parts on the manifold it is absolutely necessary to test
the manifold for tightness before the next use.
Further accessories and charging hoses for REFCO manifolds can be found in the REFCO
catalogue or on the web www.refco.ch.
Guarantee
Your new manifold has been developed according to the latest work physiological and
ergonomic aspects and corresponds to the current state of the art. The company REFCO
Manufacturing Ltd. was certified according to DIN EN ISO 9001. Constant quality controls
and careful workmanship ensure a solid functionality and allow the REFCO guarantee
according to the general terms of sale and delivery on the day of delivery. Exceptions to
this are obviously negligent treatment and damage caused by wear and tear.
Environment
The assembly aid has been developed for long-term use. In material procurement and
production, attention was paid to energy savings and environmental compatibility. REFCO
Manufacutring Ltd. is responsible for its products all its life. For this reason, REFCO Ma-
nufacturing has been certified according to DIN EN ISO 14001. When decommissioning
the device, the user should observe the applicable disposal regulations of his country.