Regular Mode
(
): This mode does not provide any degree of elevation or compensated distance, but
instead, line of sight distance only.
MENU SETUP – SELECTION of BOW, RIFLE, REGULAR MODES and UNIT OF MEASURE
There are two ARC (Angle Range Compensation) modes and one REGULAR mode. The two ARC modes
are BOW mode and RIFLE mode.
To select between these modes, first turn the unit "ON" by pressing and releasing the POWER button.
Next, press and hold the MODE button for five seconds. The "SETUP" display icon will light and the
current compensation mode will be identified by either the "BOW" symbol (
(
) lit with one of the ballistic groups (A thru J) displayed and flashing, or no indicators lit and the
message (
) flashing in the bottom of the LCD.
The modes can be cycled through in a circular fashion by pressing and releasing the mode button. The
order of modes is a follows: BOW, RIFLE A, RIFLE B, RIFLE C, RIFLE D, RIFLE E, RIFLE F, RIFLE G, RIFLE H,
RIFLE I, RIFLE J, REG, etc. When the bow selection is displayed, the "BOW" icon will flash and when
a "RIFLE: selection is displayed, the "RIFLE" icon will be steady, but the ballistic group will be flashing
toward the bottom of the LCD. When the (
bottom of the LCD.
Once the desired distance compensation mode is displayed, select it by pressing and releasing the
POWER button. Following this selection, the current unit of measure, "Y" for yards or "M" for meters will
flash in the LCD and the SETUP icon is still lit. Pressing the MODE button will toggle the unit of measure.
When the desired unit of measure is displayed, press the POWER button to accept the unit of measure

All manuals and user guides at all-guides.com
), the "RIFLE symbol
) is displayed, the message (
) will flash near the
and to return to the normal operating menu. Upon returning to the normal operating menu, the curren
compensation mode and unit of measure will be identified in the LCD as indicated below.
SETUP menu
When the unit automatically powers down, operation will always return to the normal operation (i.e
away from SETUP) with the last used ARC mode active (i.e. BOW, RIFLE, or REGULAR) along with the las
used TARGETING modes active (Standard SCAN, BULLSEYE, or BRUSH). If the unit turns off while in the
SETUP menu, the unit will always return to the last mode(s) still active.
Once the range is displayed, continue to hold the POWER button down for approximately 2 second
while holding the aiming circle on the object and keeping the unit as steady as possible so as to allow the
inclinometer enough time to measure angle. Then release the POWER button. Once you have released
the power button, a degree of angle and compensated range will be displayed beneath the line of sigh
distance as seen in the images below.