JET SMART HAND DRYER
In order to recalibrate sensors you will need to manipulate potentiometers. Do it carefully as they are
highly sensitive electronical components. Turn potentiometers with a flat head screwdriver clockwise
or counterclockwise, whichever applies.
Le
Sensor
IR SENSORS REGULATION:
P2 (Left sensor):
(+) sensitivity: turn
counterclockwise
(-) sensitivity: turn clockwise
JOFEL INDUSTRIAL S.A.
C/ La Rioja nº3 Alicante, España
Right
Sensor
Electronical plate
with poten ometers
to calibrate hand
detec on sensors
P1 (Right sensor):
(+) sensitivity: turn clockwise
(-) sensitivity: turn
counterclockwise