Pleasant Hearth WS-2417 Serie Manuel page 8

Masquer les pouces Voir aussi pour WS-2417 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CHIMNEY REQUIREMENTS
VENTING COMPONENTS
Chimney Connector:
It is also known as flue pipe or stove pipe. The chimney
connector joins the stove to the chimney. It must be a
6 inch (152mm) minimum diameter 24 gauge mild steel
black steel, or an approved air-insulated double wall
venting pipe.
Thimble:
A manufactured or site-constructed device installed in
combustible walls through which the chimney connector
passes to the chimney. It is intended to keep the walls
from igniting. Site constructed thimbles must meet
NFPA 211 Standards. Prefabricated must be suitable
for use with selected chimney and meet UL103 Type
HT Standards. Follow instructions provided by the
manufacturer for manufactured thimbles for masonry
chimney and prefabricated chimneys.
Chimney:
The chimney can be new or existing, masonry or
prefabricated and must meet the following minimum
requirements specified in Section 5B.B.
Figure 5.1 Prefabricated Exterior Chimney
CHIMNEY SYSTEMS
Prefabricated Metal Chimney
• Must be a 6 inch (152mm) diameter (ID) high
temperature chimney listed to UL 103HT (2100°F) or
CAN/ULC-S629.
• Must use components required by the manufacturer for
installation.
• Must maintain clearances required by the manufacturer
for installation.
NOTE: In Canada when using a factory-built chimney
it must be safety listed, Type UL103 HT (2100°F)
CLASS "A" or conforming to CAN/ULC-S629,
STANDARD FOR 650°C FACTORY-BUILT CHIMNEYS.
Figure 5.2 Prefabricated Interior Chimney
7

Publicité

Table des Matières
loading

Table des Matières