Bathroom using (France)
According NFC 15-100 standard, your heater has IP 24 protection and class II =
it can be installed in volume 2 or 3 of the bathroom. Make sure that any person using bath or shower can-
not touch control panel of the heater. It must not be connected to the earth.
SECURITY DISTANCE
• Wall mounted support is supplied with the appliance (5).
Do not use another support. Take care of the dimensions
around the heater. (see FIG 1).
• Fix the heater on a straight wall able to support its weight using appopiate screws and screws plug.
• First remove the wall bracket from the rear housing. Remove the 2 screws on the top of the support
(See Step1). Then pull out the top bar by pressing firmly both upper parts slotted into the rear housing
(see STEP 2)
• Slide down the support in order to remove it from the rear housing. (See STEP 3)
• Fix the support securely to the wall.
• Present the heater and engage 2 slots of the bottom parts of the support in the wall heater's rear
enclosure then pull up the heater. Then engage 2 slots of the upper parts of the support and tighten
the 2 screws in order to lock the device.
Step 1
28/06/12
11:40
Page 9
INSTALLATION
VOLUME 0 : Inside bath or shower
VOLUME 1 : on the top of volume 0, until 2,25m high
VOLUME 2 : 60 cm around volume 1 - high 3m
VOLUME 3 : 2,40 m around volume 2, high 2,25 m.