9 Maintenance and cleaning
9.3 PA liner
1
7
1
PA liner
2
Wire feed hose
3
Wire feed unit
Fig. 18
PA liner
EN - 22
NOTE
• New still unused guide spiral liners or PA liners have to be shortened to
the actual length of the hose assembly.
1 Slide guide spiral liner (1) through the wire feed hose (2) until a noticeable
resistance (6) is felt in the connector nipple.
2 Determine excess length x at the central plug (3) and pull out guide spiral
liner (1) .
3 Shorten guide spiral liner (1) by the length x and debur the cutting point.
4 Grind the spiral guide liner beginning to an angle of approx. 40°.
5 Insert guide spiral liner (1) and secure it with the liner nut (4) of the central
plug (3).
In stretched condition of the hose assembly, a counter pressure must be
noticeable.
2
6
4
Cutter
5
Liner nut
1 Sharpen the beginning of the PA liner (1) to approx. 40° with the
ABICOR BINZEL sharpener.
2 Slide PA liner (1) through the wire feed hose (2) until a noticeable
resistance (7) is felt in the connector nipple.
3 Slide holder nipple, O-ring and liner nut (5) on the PA liner (1) and tighten
the liner nut (5) under tension.
4 Slide PA liner (1) through the central socket into the wire feed unit (3).
5 Mark a PA liner (1) that is too long in front of the rollers and unscrew liner
nut (5).
6 Cut the PA liner (1) at the mark with the ABICOR BINZEL cutter (4) .
7 Sharpen the cutting point.
3
4
5
6
Central plug
7
Stop
WH and WHPP