8 Putting out of operation

7.1 Welding process

8 Putting out of operation

9 Maintenance and cleaning

EN - 20
1 Open the shielding gas cylinder.
2 Switch on the power supply.
1 Wait until the shielding gas flow has subsided.
2 Close the shut-off-valve for the gas supply.
3 Switch off the power supply.
Regular and lasting maintenance and cleaning are the prerequisite of a long
life and a perfect function. In doing so, observe the following:
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Pull the mains plug.
DANGER

Electric shock

Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.
NOTE
• The maintenance intervals given are recommended values and refer to
single-shift operation.
• Maintenance and cleaning work may only be carried out by qualified
and trained specialists.
• Always wear your personal protective clothing when performing
maintenance and cleaning work.
1 Remove adhering welding spatter.
2 Check all screw joints for tight fit.
®
BINZEL
offers repair services at the factory.