Manufacturer: Automatismi Benincà SpA.
Address: Via Capitello, 45 - 36066 Sandrigo (VI) - Italia
Herewith declares that: control unit CL.MD
complies with the following relevant provisions:
EMC guidelines: 89/336/CCE, 93/68/CEE
Low voltage guidelines: 73/23/CEE, 93/68/CEE
Benincà Luigi, Legal responsible.
Sandrigo, 08/04/2008.
WARNINGS
This manual has been especially written to be use
by qualified fitters.
None of the information provide in this manual
can be considered as being of interest for the end
users.
Preserve this manual for future needs.
The technician has to furnish all the information
related to the step by step function, the manual
and the emergency function of the operator, and to
deliver the manual to the final user.
Foresee on the supply net an onnipolar switch
or selector with distance of the contacts equal
or superior to 3 mms.
Verify that of the electrical system there is an awry
differential interrupter and overcurrent protection.
Some typologies of installation require the connec-
tion of the shutter to be link at a conductive mass of
the ground according to the regulations in force.
The electrical installation and the operating logic must
comply with the regulations in force.

TECHNICAL DATA

Contol unit supply
Operating temperature
Time of work
Output supply
Power maximum motor
Protection level
Radio receiver

EC declaration of confirmity

The leads fed with different voltages must be physi-
cally separate, or they must be suitably insulated with
additional insulation of at least 1 mm.
The leads must be secured with an additional fixture
near the terminals.
During installation, maintenance and repair, interrupt
the power supply before opening the lid to access the
electrical parts
Check all the connections again before switching on
the power.
The unused N.C. inputs must be bridged.
The descriptions and the present illustrations in this ma-
nual are not binding. Leaving the essential characteristi-
cs of the product unchanged, the manufacturer reserves
himself the right to bring any change of technical, con-
structive or commercial character without undertaking
himself to update the present publication.
230 Vac
-10°C / +60°C
2 minutes
1 motor 230 Vac
300W
IPXX
433,92 MHz integrated