NOTICE
UL applications
For UL applications, use is only permitted in Class 2 circuits in accordance
with the NEC (National Electric Code).
NOTICE
Protective Extra Low Voltage (PELV)
The device is designed in accordance with safety class III for supply with
PELV (Protective Extra-Low Voltage).
4
IP addresses
NOTICE
Valid for devices with integrated web server DDLS 5x8 ... !
"Frequency F0" devices are not available with integrated web server.
Default IP addresses:
"Frequency F0" device:
"Frequency F1" device:
"Frequency F2" device:
Resetting the IP address to default
Switch on the voltage supply while simultaneously pressing the [Mode] button.
Continue to press the [Mode] button until the AUT LED illuminates continu-
ously.
Release the [Mode] button; IP and subnet addresses are set to default.
– (see Notice)
192.168.60.101
192.168.60.102