Settings
Parameter Name
Thermostat
Cutout value S
out
Temperature unit
Diff erential S
out
Diff erential S
in
Correction of signal from S
out
Correction of signal from S
in
Delta S
, S
(S
reference)
in
out
in
Alarm
Temperature alarm delay
Delay on door alarm
Upper deviation for S
(above cutout value )
out
Lower deviation for S
(below cutout value)
out
Upper deviation for S
(above cutout value )
in
Lower deviation for S
(below cutout value)
in
S
Alarm off set during night
in
Compressor
Min. ON-time
Min. OFF-time
Cutin frequency on sensor fault *1)
Compressor stop at open door (yes/no)
Defrost
Compressor ON during defrost
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Defrost time delay (after power up)
Drip-off time
Fan start delay after defrost
Fan start temperature (>25°C=OFF)
Fan cutin during defrost
Defrost sensor *2)
Temperature alarm delay after defrost
Delay of display view after defrost
Defrost at power up
Realtime Clock
1. Defrost start. Hour
1. Defrost start. Minute
2. Defrost start. Hour
2. Defrost start. Minute
3. Defrost start. Hour
3. Defrost start. Minute
4. Defrost start. Hour
4. Defrost start. Minute
5. Defrost start. Hour
5. Defrost start. Minute
6. Defrost start. Hour
6. Defrost start. Minute
Setting af hours
Setting of minutes
Fan
Fan stop on compressor cut out
Fan stop delay
Fan stop on open door (yes/no)
Miscellaneous
Delay of output signal after start-up
Digital input control *3)
Network address (range = 0-60)
LON service pin
Access code
Used sensor type
Digital output control *4)
Active sensor
Display step = 0.5 (normal = 0.1/ Pt sensor)
Max. hold after coordinated defrost
Display sensor *5)
Manual control of outputs *6)
Relay use (alarm / light)
Comments
*1) After start-up and throughout three days and nights this value is used by the controller.
Afterwards the controller is capacble by itself to calculate the average value of previous cut-in times.
*2) Out=S
sensor used. Def=S
sensor used
out
def
*3) OFF=Not used, 1=Bus, 2=Defrost, 3=Night Cover, 4=Main switch, 5=Secondary controller Defrost In, 6 = Door
*4) OFF=Not used, 1=Main controller Defrost Out, 2=Secondary controller Defrost Out
*5) 'Aut'=Automatic Day/Night switch, 'Out'=S
*6) OFF=output not forced, 1=Comp On, 2=Def On, 3=Fan On, 4=Alarm On, 5=Dig On
When manual control is fi nished, the settting must be changed to OFF.
EKC 201C - Double thermostat
Code no. 084B7068
Display
Out
r05
r07
r08
r09
r10
r20
A03
A04
A05
A06
A07
A08
A09
c01
c02
c03
c04
d01
d02
d03
d04
d05
d06
d07
d08
d09
d10
d11
d12
d13
t01
t11
t02
t12
t03
t13
t04
t14
t05
t15
t06
t16
t07
t08
F01
F02
F03
o01
o02
o03
o04
o05
o06
o13
o14
o15
o16
o17
o18
o36
is displayed, 'In'=S
is displayed
out
in
Instructions RI.8J.A1.83 © Danfoss 04/2004
Min. value
Max. value
-50
50
°C
°F
0.1
20
0.1
20
-20
20
-20
20
0
10
0
90
0
90
0
50
-50
0
0
50
-50
0
-50
50
0
15
0
15
0
100
No
Yes
No
Yes
0
25
OFF
48
0
180
0
60
0
20
0
20
-25
26
No
Yes
Out
Def
0
200
0
30
No
Yes
OFF
23
0
59
OFF
23
0
59
OFF
23
0
59
OFF
23
0
59
OFF
23
0
59
OFF
23
0
59
0
23
0
59
No
Yes
0
15
No
Yes
0
600
OFF
6
0
990
OFF
ON
OFF
100
Pt
Ptc
OFF
2
Aut
Out
No
Yes
1
30
Aut
In
OFF
5
1
2
Unit
Factory settting
°C (°F)
3.0°C
°C
K
2.0
K
2.0
K
0.0
K
0.0
K
6.0
Min.
10
Min.
60
K
10
K
-10
K
10
K
-10
K
10.0
Min.
0
Min.
0
%
50
No
No
°C (°F)
10
Hour
8
Min.
45
Min.
0
Min.
0
Min.
0
°C (°F)
25
No
Out
Min.
90
Min.
1
No
Hour
OFF
Min.
0
Hour
OFF
Min.
0
Hour
OFF
Min.
0
Hour
OFF
Min.
0
Hour
OFF
Min.
0
Hour
OFF
Min.
0
Hour
Min.
No
Min.
0
Yes
Sec.
5
OFF
0
OFF
OFF
Pt
OFF
Out
No
Min.
20
In
OFF
1
SW = 1.2x
Actual settig
3