This section provides basic information to enable you to install and commission the MiniAir quickly.
Before installation or testing, the ARC should be contacted and system placed on test.
STEP 1. WIRING
1.
Power panel down
2.
Wire as per diagram on Page 3
3.
Connect aerial
4.
LED will show connection status
STEP 2. DIAL CAPTURE
For panels with PSTN Modems:
a.
Configure PSTN dialler of alarm panel – refer to manufacturer's guide
b.
Select DTMF (tone dialling)
c.
Select signalling format: Fast Format / Contact ID / SIA
d.
Enter any PSTN receiver telephone number (ie 01)
e.
Enter any 4 Digit chip/account number (ie 1234)
When using Fast Format, the MiniAir Installer App and My Home Alarm App are predefined with a standard Fast
Format channel configuration. Please programme the below within your control panel:
STEP 3. BELL OUTPUT
For older panels with a bell output, please only use the below method to trigger an alarm:
a.
Configure bell/siren output of alarm panel – refer to manufacturer's guide
b.
Wire the bell trigger to the MiniAir input (IN – white cable)
c.
Download the MiniAir Installer App for Android/iOS
d.
Please contact CSL to obtain log in credentials to the MiniAir Installer App & select device by serial
number/ICCID
e.
Enter Settings the select Advanced Settings
f.
Depending on your panel configuration set Input pins as: General Alarm N.O./N.C.
QUICK GUIDE
PIN
1
2
3
4
5
6
7
8
CHANNEL
Fire
Panic
Intruder
Open/Close
Fault
Bypass
Confirmed Alarm
Tamper
6