Installation (continued)

PLACEMENT

Push the cabinet against the wall . If required, level the unit by adjusting the four leveling
legs and checking the alignment of the sink using a carpenter's level .
If a gap exists, insert a spacer or shim between the middle wall mounting brace and the
wall . Secure the wall mounting brace to the wall using fastening hardware that is best
suited to your wall .

DRAINAGE

The tailpipe (not supplied) previously installed to the drain can now be connected to your
household plumbing. In some cases, your household plumbing will have to be modified
to ensure proper drainage . If so, please consult a licensed plumber to complete
needed modifications.
SUPPLY LINES
Connect the supply lines to your home's water supply as per manufacturer's instructions .
Open the hot and cold water supply valves and check to make sure they have
been installed to appropriate inlet ports . Check for leaks . Run hot and cold water
uninterrupted for about one minute to remove any residue from the lines .

Maintenance

CARTRIDGE REPLACEMENT

- Before proceeding, turn off the water supply to the faucet .
- Take off the plastic temperature indicator by hand, then use
the hex key to remove the setscrew and pull the handle
body off .
- Unscrew the cap and retaining ring, making sure not to
damage the threads .
- Pull out the cartridge and replace it with a new 35 mm
(1 .4 in .) ceramic cartridge .
- Reinstall the retaining ring making sure the cartridge is
properly seated within the faucet body .
- Reinstall the cap and tighten gently by hand .
- Reinstall the handle body and lock it in place using the hex
key and the setscrew . Do not over tighten .
- Reinstall the temperature indicator into the handle body
making sure the red is on the left and the blue is on the right .
QL029
All manuals and user guides at all-guides.com
10
10
Cabinet Cross Section
Some Components Removed For Clarity
Temperature indicator
Setscrew
Cap
Retaining ring
Cartridge
Faucet Body
Handle
Body