EN
TECHNICAL DATA
Minimum dynamic pressure:_________________________________________________________0.5 bar
Maximum operational pressure:________________________________________________________5 bar
Recommended operational pressure:_________________________________________________1-5 bar
It's recommended to use a pressure reducer in case of
static pressure superior than 5 bar inside the waterpipe.
Maximum hot water temperature:_______________________________________________________80°C
INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE
In order to get your device work correctly and fi ne in time, must ensure compliance with the
mode of installation and maintenance described in this booklet. Relying on a qualifi ed plumber.
Make sure that the system is free from all debris and impurities existing.
INSTALLATION
Fig. 1: Fix the body to the fi xing plate.
Fig. 2-3: Make a hole into the wall with a minimum measure of 150 mm - 5.90 in, 280 mm –
11.02 in, and MIN 80 mm - 3.14 in, MAX 90 mm – 3.54 in depth.
N.B.: The minimum and maximum measure have to be considered in relation to the fi nished
wall, cladding included.
Fig. 4-5: Fix the recessed body taking in consideration the perpendicularity, both vertical and
horizontal, by using a spirit level.
Fig. 6: Connect the body to the hydric system. It's recommended to use hemp or PTEF for
granting the endurance.
Fig. 7: Insert the fi nishing rosette on the cartridge ring and move the ring of the spout against
the wall.
Fig. 8: Place the spout on the insert. Screw the screw, using a 7 mm fork key, until fully locked.
After connecting the body to the system, turn on the stopcocks and check that the mixer tap
unit operates correctly. Keep the tap pressurised for a few minutes checking eventual leaks.
Fig. 9: Complete the wall leaving openings around the spout and the ring, so that they are co-
vered with rosettes.
Fig. 10: Screw the bell on the headwork; insert the fi nishing rosette on the bell. Insert the han-
dle by fi xing it with the screw. Move the fi nishing rosette of the spout against the wall.
CLEANING
In order to obtain a correct cleanliness, exclusively wash them with soap and water, rewash and
dry them with a soft towel and deerskin. Avoid the usage of alcohol, solvents, solid or liquid
detergents which contain corrosive or acidic substances, abrasive sponges, swab with metallic
strings because they could irreversibly compromise the surfaces.
THE USAGE OF THIS KIND OF DETERGNETS DURING THE CLEANING OF THE MIXER EXCLUDE
IB RUBINETTERIE FROM ANY WARRANTY OBLIGATION.
All manuals and user guides at all-guides.com