Troubleshooting (cont'd)
Symptom*
Distortion, dialing
difficulty
Dead circuit
* Wet cables may cause most of these symptoms and may cause multiple symptoms to
appear at the same time.
14
Possible Cause /
Troubleshooting Step
(1) When using the test
set in Talk mode,
the voltage will be
lower than normal.
(2a) When using the
test set in Monitor
mode, or with the
test set discon-
nected, the voltage
will be normal.
(2b) When using the
test set in Monitor
mode, or with the
test set discon-
nected, the voltage
will be lower than
normal.
Open circuit or
short circuit
Explanation
(2a) This indicates a high-resistance fault, which
restricts the amount of current flowing
through the circuit. Possible faults include
a poor connection, wet cables, or a line
extender failure.
(2b) This indicates a partial short circuit.
Break the circuit down into sections and check
each section for continuity.