HIGH CAPACITY THERMOSTATIC RADIATOR VALVES V110D, E, F
5. Radiator with T104F control mounted on V110E
angle pattern valve body. As illustrated, the radiator
was originally installed close to a corner, or in an
alcove, precluding use of a horizontally mounted
control. Because the control must be mounted verti-
cally, a T104F remote sensor model is required, with
the sensor mounted on a nearby wall where air circu-
lation is unobstructed.
6. Convector with T104F control mounted on V110D
straight pattern valve body. Because the control is
mounted inside an enclosure, a control with remote
sensor must be used. The sensor is installed a mini-
mum of 3" beneath the heating coils in the cold air
return. The setpoint dial may be adjusted through a
small access door.
7. Radiator with T104F control mounted on V110D
straight valve body. Because air circulation around
the valve body is obstructed by a curtain, a control
with remote sensor must be used. The sensor is
installed on a nearby wall to sense representative
room temperature.
8. Radiator with T104B control mounted on V110D
straight pattern valve body. Because the valve is
installed within an enclosure and does not have easy
access, a remote sensor and setpoint control is
required. The combination remote sensor/setpoint
must be mounted on a nearby wall where air circula-
tion is unobstructed and access is adequate. Mount-
ing on a hot cabinet would cause false sensing.
9. Convector cabinet with T104B control mounted on
V110E angle pattern valve body. Because the valve is
installed within an enclosure and does not have easy
access, a remote sensor and setpoint control is
required. The combination remote sensor/setpoint
must be mounted on a nearby wall where air circula-
tion is unobstructed and access is adequate.
10. Convector with T104C control mounted on V110D
straight pattern valve body. Because the valve is
installed within an enclosure and does not have easy
access, a remote sensor and setpoint type control is
required. When the setpoint dial is to be mounted on
the hot convector cover, the sensor must be separate
from the dial. The sensor is mounted a minimum of
3" beneath the heating coils in the cold air return.
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
www.resideo.com
62-2014EF—02 M.S. Rev. 03-20 | Printed in United States
© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.
Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l'autorisation d'Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.
M32168
5
7
9
M3190
M4640
6
8
M16835
M4638
10
M1293

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

V110eV110f

Table des Matières