CAUTION: Most common scrubber type pads will scratch the liner. If a commercially available stainless
steel cleaner is used, it is important to read the labels for chlorine compounds. Chlorine is a corrosive substance.
If these compounds are present, rinse thoroughly and dry with a soft lint-free cloth. Follow polish manufacturer's
instructions. Always wipe stainless steel surfaces with the grain. Never wipe across the grain. After cleaning,
reinstall the filters carefully.
HALOGEN LIGHT BULBS:
Blowers are designed for 50 watt MR16-GU10 Halogen Lamp. They can be purchased at most home or grocery
stores, e.g., Lowe's, Home Depot, McCoy's, Menards or Ace True Value.
PART 6
Electrical Connection
IMPORTANT: Copy this page and the next page for your electrical installer.
WARNING! Ensure that the power supply is disconnected before proceeding. Verify that the power supply
matches the ratings found on the appliance data label before proceeding. The complete appliance must be
properly grounded at all times when electrical power is applied. Do not ground the appliance with the neutral
(white) house supply wire. A separate ground wire must be utilized. Failure to complete electrical connections
properly may result in damaged or non-functional systems. Follow instructions carefully to ensure proper
installation.
It is the owner's responsibility to ensure that a qualified person performs the electrical connection of this appliance.
The electrical installation, including minimum supply wire size, must comply with the National Electric Code
ANSI/NFPA 70-1990 (or latest revision) and local codes and ordinances. A copy of this standard may be obtained
from: National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02269-9101
INSTRUCTIONS: A 15 to 20 amp electrical service is recommended for proper electrical supply. Before
determining, calculate amp ratings based on the product label found on the 06 W/P series module. Always observe
local building codes. Always use a dedicated circuit. Line load is calculated by adding the amperage of the
halogen lights to the rated amperage of the ventilator. If the ventilator is rated in watts rather than amps, divide the
watts by 120 and this will give you the amperage rating.
CAUTION: The neutral wire (usually white) for the ventilator must connect to the same neutral wire that
comes from the electrical panel to the liner.
Factory Installed Variable-Speed Wiring Details
Black
120 volt AC from electrical panel (usually black)
White
Neutral from electrical panel (white)
Green
Ground from elecrital panel (usually green)
Installation Instructions, Revised 05/13/13
Wiring Diagram
01A/02A Series Models
House Electrical
Panel
White (N)
120V Black (L)
BLK
Liner
Green
WHT
GRN
11