Use Of The Cutting Dies; Use Of The Punch Adapter; Explanation Of The Application Range; Mounting Instructions - Textron Klauke EK 120UNV-L Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Instruction Manual Universal tool
EK 120UNV-L
4.1.2 Use of cutting dies
Three diffent types of cutting dies are available (pic. 26,
28, 30). The UC 26 is optimised on copper and alumini-
um cables/conductors ≤ 26 mm Ø. The UC 40 can cut
all copper and aluminium cables/conductors < 40 mm Ø.
The larger cables/conductors show the best results res-
pectively the least deformations.
Attention
Do only cut copper and aluminium cables/con-
ductors with UC 26 and UC 40!
For cutting ACSR conductors you must only use the
UCACSR cutting blades.
Attention
Cutting ACSR conductors or steel fortifi ed
cables do always wear safety glasses.
Fractions of reenforced steel conductors can be propelled
towards the operator with high speed and could cause
severe injuries.
When cutting threaded rods they must be in a right angle
to the cutting blades to provide a clean cut. The threa-
ded rods must be cleaned of chips prior to cutting. The
cutting cycle should be proceeded until the blades have
reached their fi nal position in order to provide clean cut-
ting edges.
The DIN rail cutting dies are equipped with a sheet metal
guide which facilitate a cut in a right angle.
When the cut is completed the retraction is provided by
actuating the retract button (pic. 1.4) once.

4.1.3 Use of the punch adapter

The advance (penetration) of the punch into the die must
be observed carefully. As soon as the sheet metal is pun-
ched the punching cycle must be terminated by releasing
the trigger (pic. 1, 3).
The retraction is provided by actuating the retract button
(pic. 1, 4) once.
Attention
If the punching cycle is not terminated after the
sheet metal is punched the punch will contact
the die which might result in fracture of one or
the other.
HE.13471_D © 09/2010
All manuals and user guides at all-guides.com

4.2 Explanation of the application range

The electric hydraulic unit can be operated with a large
number of various crimping and cutting dies.
Attention
Do only crimp those connecting materials men-
tioned in Tab. 2.
If different conducting materials have to be crimped, ple-
ase contact the manufacturer.
Attention
Do not crimp on live cables or conduc-
tors
The unit is a hand held tool and it is not supposed to be
restrained in a vise. It is not allowed to use the tool in a
stationary application.
The tool is not designed for continued operations. After a
sequence of approximately 40-50 completed cycles you
have to make a break of 15 min. to give the tool time to
cool down.
Attention
Too intensive use can cause heat damages for
the tool
Attention
During the operation of electric engines sparks
can occur which might ignite highly infl ammab-
le or explosive liquids and materials
Attention
Electric-hydraulic tools should not be operated
in pouring rain or under water.

4.3 Mounting instructions

Please read the assembly instructions in our general ca-
talogue.
Attention
Even if the code number is identical only those
dies should be used which are suitable for the
material.
3
GB

Publicité

Table des Matières
loading