During COOL MODE test running , the default target
outlet water temperature is 7°C.
operate until the water temperature drops to a
certain value or the next command is received.
When the HEAT MODE RUNNING is selected, the
following page will be displayed:
11 TEST RUN
Test run is on.
Heat mode is on.
Leaving water temperature is
15°C.
OK
CONFIRM
During HEAT MODE test running , the default target
outlet water
temperature
(internal
backup heater) will turn on after the
compressor runs for 10 min. After the IBH runs for 3
minutes, the IBH will turn off, the heat pump will
operate
until
the
water
to a certain
value or the next
received.
When the DHW MODE RUNNING is selected, the
following page will be displayed:
11 TEST RUN
Test run is on.
DHW mode is on.
Water flow temperature. is 45°C
Water tank temperature. is 30°C
OK
CONFIRM
During
DHW MODE test
target temperature of the domestic water is 55°C.
The TBH(tank boost heater) will turn on after the
compressor runs for 10min. The TBH will turn off 3
minutes later, the heat pump will operate until
the water temperature increase to a certain value or
the next command is received.
During test run, all buttons except OK are invalid . If
you want to turn off the test run, please press
OK. For example, when the unit is in air purge
mode, after you press OK, the following page will be
displayed:
11 TEST RUN
Do you want to turn off the test run
(AIR PURGE)function?
NO
OK
CONFIRM
Press
to scroll the cursor to YES and press OK. The
test run will turn off.
The unit will
is
35°C.
The
IBH
temperature increase
command
is
running, the
default
YES
8.4.12 AUTO RESTART
The AUTO RESTART function is used to select
whether the unit reapplies the user interface
settings at the time when power returns after a
power supply failure.
Go to MENU> FOR SERVICEMAN>13.AUTO RESTART
13 AUTO RESTART
13.1 COOL/HEAT MODE
13.2 DHW MODE
ADJUST
The AUTO RESTART function reapplies the user
interface settings at the time of the power supply
failure. If this function is disabled, when power
returns after a power supply failure, the unit won't
auto restart.
8.4.13 POWER INPUT LIMITATION
How to set the POWER INPUT LIMITATION
Go to MENU> FOR SERVICEMAN>14.POWER INPUT
LIMITATION
14 POWER INPUT LIMITATION
14.1 POWER LIMITATION
ADJUST
8.4.14 INPUT DEFINE
How to set the INPUT DEFINE
Go to MENU> FOR SERVICEMAN> 15.INPUT DEFINE
15 INPUT DEFINE
15.1 ON/OFF(M1M2)
15.2 SMART GRID
15.3 T1b(Tw2)
15.4 Tbt1
15.5 Tbt2
ADJUST
15 INPUT DEFINE
15.6 T a
15.7 Ta-adj
15.8 SOLAR INPUT
15.9 F-PIPE LENGTH
15.10 RT/Ta_PCB
ADJUST
35
YES
NON
0
REMOTE
NON
NON
NON
NON
HMI
-2°C
NON
10m
NON
V.2