SR131A and SR231A
Operating Instructions for SR131 and SR231 Safety Monitoring Relays
Safety module for a total of 2 magnetic switches with a
normally open and a normally closed contact each
according to EN 60947-5-3
Module de sécurité pour au total 2 interrupteurs
magnétiques comportant chacun un contact à
fermeture et un contact à ouverture
selon EN 60947-5-3
Sicherheitsbaustein für insgesamt 2 Magnetschalter mit
jeweils einem Schließer- und einem Öffnerkontakt
gemäß EN 60947-5-3
Dimensions / Encombrements / Maße
114 mm
(4.48 in)
SR131....
114 mm
(4.48 in)
SR231...
SR231...
SR131...
1/8
22.5 mm
(0.89 in)
22.5 mm
(0.89 in)
1 3 2 3
S 1 2 S
2 1 3
S 1 1
Y 1 Y
A 1
R
1
S R 2 3
T Y P E
A 1 /A 2
F u se
K 1 /K 2
R
1
S R 1 3
T Y P E
A 1/ A 2
F u se
A 1
A 1
1 3 2 3
K 1 /K 2
K 1
Y 4 4
Y 3 4
1 4 2 4
A 1
K 2
A 1
1 3 2 3
1 4
Y 4 4
K 1
Y 3 4
2 4
A 2
S 2 3
S 2 2
S 2 1
Y 4 4
Y 3 4
1 4 2 4
K 2
SR231...
Terminal marking/ Repérage des bomes /Klemmenanzeiger
S11
S12
S13
23
A1
Y2
Y4
13
A2
Y34
Y44
14
S21
S22
S23
24
SR131...
Application
Safety systems are comprised of many components. No one safety
component will insure the safety of the system. The design of the complete
safety system should be considered before you begin. It is very important to
follow applicable safety standards when installing and wiring these
components.
The unit SR131/SR231 is a safety module for monitoring of magnetic
switches with a normally closed and a normally open contact each.
The unit is suitable for the following applications up to control category 4
in accordance with EN 954:
• Safety door locks with magnetic switches.
• Monitoring of several doors with one module.
The module provides two potential free safety contacts and two solid-state
signal outputs. In case of a direct use in a category 4 cut-off circuit the two
safety contacts 13-14 and 23-24 must be connected in series. The contact
multiplication by means of contactors with guided contacts is shown in the
wiring diagram.
Due to the redundant design of the unit the occurrence of a single fault does
not lead to the loss of the safety function. All detected faults are displayed
through the solid-state signal output Y34.
After connecting the supply voltage to the terminals A1-A2, the module runs
an internal test. During this test, all LEDs in the panel in the device cover
are illuminated for 2 seconds and the transistor outputs Y34 / Y44 are
activated in this time.
If all connected magnetic switches are actuated and the starting circuit
Y1-Y2 is closed, the safety outputs are activated. The contact change
between normally closed and normally open of a magnetic switch must
occur within a period of 0.5 seconds. An unused input (e.g. S21-S23) must
be jumpered.
It is imperative that an external fuse be connected as shown on the
"WIRING DIAGRAM FOR MODULE SR131/SR231 SAFETY RELAY".
For maximum protection of the outputs, please refer to "TECHNICAL
DATA".
S11
S12
S13
23
A1
Y1
Y2
13
A2
Y34
Y44
14
S21
S22
S23 24
SR231...
10/2003

Publicité

loading

Sommaire des Matières pour Omron SR131A

  • Page 1 Safety Technology & Innovation SR131A and SR231A Operating Instructions for SR131 and SR231 Safety Monitoring Relays Safety module for a total of 2 magnetic switches with a normally open and a normally closed contact each according to EN 60947-5-3 SR231...
  • Page 2 Operating Instructions for SR131 and SR231 Safety Monitoring Relays Note WARNING There are no user serviceable components in the module. For safety circuits according to EN 60204-1 / EN418 safety devices must use only the FAILURE TO PROTECT hard contact outputs between terminals 13-14 and 23-24. •...
  • Page 3 XPS-DMB Operating Instructions for SR131 and SR231 Safety Monitoring Relays Wiring diagram for SR131/231 DANGER Schéma de raccordement pour SR131/231 Anschlußplan für SR131/231 HAZARDOUS VOLTAGE • Disconnect all power before working on equipment. Electric shock will result in death or serious injury. Protective guard 1, closed Protecteur 1, fermé...
  • Page 4 Operating Instructions for SR131 and SR231 Safety Monitoring Relays System diagnostics LEDs on the front cover: Diagnostic du système à l'aide des DEL dans le couvercle du boîtier: Systemdiagnose mittels LED-Anzeige im Gehäusedeckel: Power - A1/A2 Arrangement of LEDs in the cover Disposition des DEL dans le couvercle du boîtier Fault Anordnung der Leuchtdioden im Gehäusedeckel...
  • Page 5 XPS-DMB Operating Instructions for SR131 and SR231 Safety Monitoring Relays Functional Diagram SR131/231 Diagramme fonctionnel du SR131/231 Funktionsdiagramm SR131/231 Magnetic switch 1 (S11-S12) Interrupteur magnétique 1 (S11-S12) Magnetschalter 1 (S11-S12) Magnetic switch 1 (S11-S13) Interrupteur magnétique 1 (S11-S13) Magnetschalter 1 (S11-S13) Magnetic switch 2 (S21-S22) Interrupteur magnétique 2 (S21-S22) Magnetschalter 2 (S21-S22)
  • Page 6: Technical Data

    Operating Instructions for SR131 and SR231 Safety Monitoring Relays Electrical life of the output contacts determined by EN 60947-5-1 / table C2 Durée de vie des contacts de sortie selon EN 60947-5-1 / tableau C2 Lebensdauer der Ausgangskontakte gemäß EN 60947-5-1 / Tabelle C2 AC15: 230V DC13: 24V Operation Cycles...
  • Page 7 XPS-DMB Operating Instructions for SR131 and SR231 Safety Monitoring Relays - Mounting: - Gehäusebefestigung: - Fixation du boîtier: Mounting on 35 mm DIN rail Schnappbefestigung auf 35 mm Encliquetage sur profile chapeau 35 mm according to DIN EN 50022 Normschiene nach DIN EN 50022 selon DIN EN 50022 - Degree of protection according to IEC 529: - Schutzart gemäß...
  • Page 8 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu Authorized Distributor: Automation Control Systems •...

Ce manuel est également adapté pour:

Sr231a