Operation:
The machine must always be standing upright when in use.
Transport:
The machine must be transported in upright position.
Starting and stoppage:
Start and stop the machine via connection to an earthed wall socket. If the machine has been stopped,
it must not be restarted for 5-6 minutes.
Drainage:
Once the collection vessel is full, the dehumidifier stops automatically. A red light is visible through the
front-grid. Alternatively, the water may be drained off by connecting a hose to the dehumidifier's pipe outlet.
Cleaning:
Blow through the condenser and evaporator with compressed air. In dusty environments, this should be done
once a week.
Wiring diagram:
The wiring diagram can also be found inside the machine's cover.
Maintenance/Service:
Warning! Before carrying out maintenance work on the dehumidifier, the machine should be disconnected
from the mains by pulling the plug out of the wall socket.
The following points should be checked annually by an authorised person:
• Cleaning the evaporator, condenser and fan.
• Cleaning of the condensation water outlet.
• Refrigeration system check.
• Electrical check.
Service:
Service may only be carried out by an authorised person or the manufacturer.
Any maintenance work on the electrical system must be carried out by an authorised electrician!
Any maintenace work on the refrigeration system must be carried out by an authorised refrigeration system
mechanic!
• This product is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the product by a person responsible for their safety.
• The product is, however, well suited for use in environments where persons (including children) with
reduced physical or mental capabilities or with decreased discernment are staying.
• Children should be supervised to ensure that they do not play with the product.

TECHNICAL DATA

The dehumidifiers technical data
Dimensions, HxWxL:
Weight:
Voltage:
Power:
Fuse:
Operating range, temperature:
Operating rang, humidity:
Air flow:
Refrigerant:
Bears the S-label & CE approved.
8
All manuals and user guides at all-guides.com
560 x 370 x 390mm
30 kg
230 V, 50 Hz
640 W
10 A, træg
+7° -+ 35°C
20 – 99% RH
500 m
/hour
3
R 134 a