Operation:
The machine must always be standing upright when in use.
Transport:
The machine must be transported in upright position.
Starting and stoppage:
The machine must be powered via an earthed wall socket. Wait 5 to 6 minutes before restarting after the
machine has stopped.
Drain:
Connect a 1/2" water hose to the pipe connection at the side of the machine and lead the hose to a water
drain or large receptacle. N.B. Ensure that the receptacle does not overflow
Cleaning:
Blow the condenser and evaporator clean using compressed air. In a dusty environment this should be done
regularly.
Circuit diagram:
The circuit diagram is located on the inside of the machine cover.
Maintenance/Service:
Warning. Power supply to the machine must be disconnected before attempting to do any maintenance. This
is done by unplugging the wall socket.
Check the following items every year. Each item shall be checked by an authorized person.
• Cleaning the evaporator, condenser and fan.
• Cleaning of the condensation water outlet.
• Refrigeration system check.
• Electrical check.
Service:
Service may only be carried out by an authorised person or the manufacturer.
Any maintenance work on the electrical system must be carried out by an authorised electrician!
Any maintenace work on the refrigeration system must be carried out by an authorised refrigeration system
mechanic!
• This product is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the product by a person responsible for their safety.
• The product is, however, well suited for use in environments where persons (including children) with
reduced physical or mental capabilities or with decreased discernment are staying.
• Children should be supervised to ensure that they do not play with the product.

TECHNICAL DATA

The dehumidifiers technical data.
Size, H x W x L:
Weight:
Rated voltage:
Rated power:
Fuse:
Working range, temperature:
Working range, humidity:
Air flow:
Refrigerant:
S-marked and CE approved.
8
All manuals and user guides at all-guides.com
990 x 510 x 490 mm
43 kg
230 V, 50 Hz
775 W
10 A, anti-surge fuse
+7°- +35°C
20-99 % RH
700 m
/h
3
R 134 A