Associating the detector with the system
The control unit must be in Maintenance mode (press the ON
and OFF buttons simultaneously for 5 seconds on an already
recognized control unit until the control unit emits a beep).
The front panel LED flashes.
Open the battery cover of the control unit.
Go to the "Product" menu on the
control unit
- Press the "ON" button for more than 5
sec. on an already recognized control
unit,
The control unit emits a beep and the
front panel LED is steady.
Record the detector
- Press the detector's test button
until the control unit emits a
beep.
- The control button emits a
beep and its "1" LED (detector)
switches on (this LED is already
lit if a detection element has
already been recorded).
- Close the battery cover of the
control unit.
- 17 -
All manuals and user guides at all-guides.com
Beeep
5 sec.
BeeeP
BeeeP
1
alarm
1
2
tamper
3
battery
4
supervision
5
means of entry
remove
test
System test
• Trigger a detection action
(see manufacturer's instructions for the associated sensor)
• Check that the detection occurs correctly
(see § Operating principle)
Technical characteristics
- Radio range: 200 to 300 metres outside depending on the
equipment associated (the range can be altered depending
on the installation conditions and the electromagnetic
environment)
- Radio frequencies: 434 and 868 MHz, class I
- Power supply: 2 LR03 (or AAA) type 1.5 V alkaline batteries
- Average stand-by mode consumption: 12 µA
- Average consumption for transmission: 15 mA
- Autonomy: 3 years for normal use
- Maximum cable length between transmitter and sensor:
3 metres
- Protection index: IP30
- Use: dry interior only
- Dimensions: 102 x 32.5 x 31 mm
- Operating and storage temperature: -10°C / +55°C
Device complying with the requirements of
the R&TTE 1999/5/EC directive
Because of changes in standards and equipment, the characteristics given in the text
and the illustrations of this document are not binding unless confirmed by Delta Dore.