Installation and operating manual
Modular switch receiver 1 channel 5A
Ref. 10020070
1. General
1.1 Use
0
The 1 channel modular switch receiver
0
LINE (see compatibility table §6.1). It is used for switching
switch transmitters or sensors
2
loads, e.g. incandescent, halogen, power contactor or small motors. Thanks to its output
changeover contact, it enables, through simple cabling, the changeover (of the power supply)
of the load for applications such as switching the heating off upon opening of the windows.
Before any use, the transmitters must be allocated to a receiver. Each sensor or transmitter
can control an unlimited number of receivers.
Note: Read the operating manual carefully before initial use.
1.2 Guarantee terms
This operating manual is an integral part of the device and our guarantee terms. It must always
be delivered to the user. We reserve the right to modify the technical design of these devices
0
without warning. TRI
SYS products are manufactured and their quality checked by making
2
use of the latest technologies and taking into account the applicable national and international
directives. If nevertheless a fault arises, TRI
follows, without prejudicing the rights of the end customer that arise from the sales contract
with his reseller.
If the event of exercising of a legitimate and regular right, TRI
rectify the device fault or supply a fault-free device. Any claim beyond this and all claims for
consequential damages are excluded.
A legitimate fault exists if the device cannot be used at the time of delivery to the end customer
because of a design or manufacturing defect or if its practical use is severely limited. The
guarantee is void in cases of natural wear and tear, incorrect use, incorrect connection, where
the device has been repaired or external influence. The guarantee period is 24 months (from
the date of invoicing). French law applies to the regulation of guarantee rights.
1.3 Recycling of the device
To recycle the device, conform to the legislation and standards in force in the country of use.
2. Safety
WARNI
WARNING! Risk of electric shocks! (See UTE C18-150) The device contains
live internal components. Risk of wounds or injuries if contact occurs! All work
on the mains supply network and the device must only be carried out by
authorised professional technicians.
• Before carrying out any work, switch-off and isolate the device.
• Secure the device to prevent it being switched back on.
• Check the device is in a zero-volts state.
• Carefully reclose the casing before reconnecting to mains power.
Observe the following points:
• The laws, standards and directives in force.
• Best practice at the time of installation.
• The device operating manual.
• An operating manual can only give general instructions. They must be interpreted in the
context of a specific installation.
The device is intended solely for use conforming to its purpose. Any repairs or modifications
by the user are forbidden! Do not use with other devices the operation of which could endanger
people, animals or property.
3. Technical characteristics
General characteristics
Transmission frequency
Category receiver
Power supply
Terminal capacity
Output (zero potential)
1 changeover contact micro distance (µ)
opening contacts, I
=100mA
min
Ambient temperature
Storage temperature
Ambient humidity
Degree of protection
Installation altitude
Range in buildings
20m, through 3 walls at most
Masonry
Reinforced concrete
10m, through 1 wall/ceiling at most
Plasterboard / wood
30m, through 5 walls at most
Remarque: The signal strength between the transmitter and the receiver decreases as the
distance increases. Where there is a line of sight connection, the range is approximately 30m
in corridors and 100 m in large workshops or halls.
0
The range can be increased with an
2
Respect a minimum range of 10 cm between transmitter and receiver.
TOC11908NUcc_0120
EN
LINE 10020070 is used to receive radio signals from
2
0
SYS undertakes to remedy the default as
2
0
SYS, may at its sole discretion,
2
868.3 MHZ
2
230V
/ 50 Hz
2
2
1x1,5
to 2,5
max rigid
max µ5A/1100VA resistive (cos φ=1)
400W incandescent/halogen
150W inductive (cos φ= 0,4 à 0,6)
from -10°C to +45°C
from -20°C to +80°C
from 0 to 75%hr
(without condensation)
IP20 with plastron
2000m max.
.
LINE repeater
4. Installation and initial use
4.1 Safety instructions
The installation and initial use must only be performed by authorised qualified electricians. The
electrical installation must be placed off-load before connection it to the mains (230V~/50Hz).
Conform to the legislation and standards in force in the country of use.
4.2 Installation
This product is designed for indoor use. It is maintenance free.
• This product is intended for installation only on horizontal DIN rail, in an electrical panel
(mounted on a vertical wall) with compulsory installation of a plastron which will be connected
to the ground of the installation if it is metallic.
• For compliance with the standard reference, height of the plastron (compared to the above
DIN rail) must not exceed 48mm with a minimum thickness of 1mm.
• NEVER install the receiver in a metal casing or in the immediate vicinity of large metallic
objects.
• Installation on the ground or close to the ground is not recommended. Thank you to refer to
the installation standards of each country.
• The receiver has one zero-volt changeover output: NF-C is the open contact, C-NO is the
close contact.
• Protect the supply line with a circuit breaker 2A curve C adapted to the installation place.
• For the controlled power over 400W, the output contact must be supplied with the same
supply line as the product, but protected separately with a circuit breaker 2A curve C adapted
to the installation place.
Connection drawing for a
lighting application ≤ 400W:
L
N
C2A
4.3 Initial use
• Connect power to the electrical installation after it has been installed.
• Program the transmitter on the receiver (see § 5).
5. Programming
For programming the receiver must be connected to the mains. The programming is conserved
during a power failure.
A small insulated screwdriver shall be used on the unit to activate the LRN or CLR buttons.
5.1 Programming mode or transmitter deletion mode
N.B.! A transmitter must not be further away than 5 m from receiver in learn mode. The
receiver has a limited range!
To enter the programming mode, short press (approximately 0,5s) the LRN button. This mode
is confirmed by the regular flashing of LED.
a) To associate a transmitter simply press on one of the switches or press the LRN button
(see §6.2). The receiver will acknowledge its recording in memory by maintaining the LED
on for 4 seconds. As soon as flashing LED starts again, another transmitter can be
associated or cleared.
b) To clear a transmitter simply press on one of the switches or press the LRN button of the
7mm
desired sensor (see §6.2). The receiver will acknowledge its clearing off the memory by
maintaining the LED off for 4 seconds. As soon as flashing LED starts again, another
transmitter can be associated or cleared.
To exit programming mode, short press (approximately 0.5s) the LRN button. The output is
confirmed by the stopping of regular flashing of the LED.
Notes:
– No transmitter is programmed in the receiver as supplied state.
– When using BMS products, mono or multi-channel, programming must be performed alone
and channel by channel: you must exit the programming mode between each channel, by
short press the LRN button and within 5 seconds after the start of LED acquittal.
– Up to 32 switch, transmitters and sensors can be allocated to each channel.
– If the memory is full, the receiver exits programming mode upon an additional association
attempt.
– The transmitters are alternatively programmed or cleared in the event of several activations!
– If no button is pressed, learn mode stop automatically after 30 s.
5.2 Clearing off all the programmed transmitters
Press the CLR button for approximately 2s. Clearing is confirmed by the regular flashing of LED.
The receiver returns automatically to programming mode.
To exit programming mode, short press (approximately 0,5s) the LRN button. The output is
confirmed by the stopping of regular flashing of the LED.
Connection drawing for a resistive
load application ≤ 1100W:
LN : Main
L
230V~ / 50 Hz
N
C2A
Output NO:
- load disconnected when off
Output NF:
- load connected when off
Gate C:
- power contact
Note:
- The two L terminals are
Internally connected
- See section 6.1 for
changeover of state/
operating
C6A
LED display
Output status
Programming
LRN button
Learn mode
CLR button
Cancels all
transmitters
Load
3/4