Technical Data

Rain water tank pump
Art. No
Service connection
Rated input
Max. immersion
Max. delivered quantity
Max. head of delivery
Max. suction
Max. Water temperature
Rain water tank pump Service con-
nection
Degree of protection
Weight
Read and understand the operating
instructions before using the appliance. Familiarise
with the control elements and how to use the
appliance properly. Abide by all the safety measures
stated in the service manual. Act responsibly toward
third parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
This appliance can be used by child-
ren aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of
the appliance in a safe way and un-
derstand the hazards involved.
Children shall not play with the
appliance.
Cleaning and user maintenance
shall not be made by children wit-
hout supervision.

Specified Conditions Of Use

The pump is solely used for drainage and for pum-
RFP 5200
ping into and out of containers in the house, garden,
farm and agriculture and only for water. Respecting
05270
technical data and safety precautions.
230 V~50Hz
Do not use this product in any other way as stated
350 W
for normal use. Not observing general regulations
7 m
in force and instructions from this manual does not
make the manufacturer liable for damages.
5200 l/h
11 m
Do not use pump at outside temperatures over 40 °C
or under 0 °C
3 mm
35 °C
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
3/4" AG
When used in this manner, its service life is curtailed
IPX8
correspondingly. In these cases, then, use a time
switch to secure sufficient idle periods between
4,1 kg
cycles of operation.
Do not leave the pump unattended while in
operation in order to prevent subsequent
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
do not plan on using it.
Do not use the pump for drinking water!
The pump must not be used to pump waste
water.

Emergency procedure

Conduct a first-aid procedure adequate to the injury
and summon qualified medical attendance as quickly
as possible. Protect the injured person from further
harm and calm them down. If you seek help, state the
following pieces of information: 1. Accident site, 2.
Accident type, 3. Number of injured persons, 4. Injury
type(s)
Symbols
WARNING/CAUTION!
WARNING - Read the operating instruc-
tions to reduce the risk of injury.
Unplug the machine before any work
on it.
Cable pulling / transport prohibited
ENGLISH
13