3. Trial
The user must "Start the Pump before the Machine, and Turn off the Machine before the Pump", or
i.
the machine will be damaged.
j.
Before start the heat pump, please check for any leakage of water; and set suitable temperature in
the thermostat, and then switch on power supply.
k.
In order to protect the swimming pool heat pump, the machine is equipped with a time lag starting
function, the fan will run 1 minute earlier than the compressor when starting the machine, and it will
stop running 1 minute later than the compressor when power off the machine.
l.
After the swimming pool heat pump start up, please kindly checking for any abnormal noise from the
machine.
G. Maintenance
In winter season when you don't swim:
a. Cut off power supply to prevent any machine damage.
b. Drain water clear of the machine.
c. Cover the machine body when not in use.
"CUT OFF"
power supply of the heat pump
before cleaning, examination and repairing
!!Important:
Unscrew the water nozzle of inlet
pipe to let the water flow out.
When the water in machine freezes in
winter season, the titanium heat exchanger
may be damaged.
13