Troubleshooting Guide - United States Stove Company KP60 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to "OFF" does
not disconnect all power to the electrical components of the stove.
• Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All other
work should be done by a trained technician.
PROBLEM
Orange, lazy flame
excessive fuel build-
up in the burnpot
PROBLEM
Fire goes out or stove
shuts down.
PROBLEM
Stove does not start
a fire when the "ON"
button is pushed
PROBLEM
Experiencing
low
exhaust pressure
ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.
IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT
© 2021 United States Stove Company
CAUSE: To rich air/fuel mixture
Clean out the burnpot and burnpot housing
Make sure that the viewing door is closed and sealed properly. If not, adjust door catch and/
or replace door gaskets.
Check that all outside connections are clear of any obstructions.
Check the exhaust system; clean as needed.
CAUSE: Burnpot burns out of fuel
Hopper is empty, refill the hopper.
Loss of draft pressure. Make sure that the viewing door is closed and sealed properly. If not,
adjust door catch and/or replace door gaskets. Check that all outside connections are clear
of any obstructions. Check the exhaust system; clean as needed.
Check that the pressure switch connection to the firebox is free of ash or clear of obstructions.
Auger system is jammed or there is a "bridging" of the fuel in the hopper, preventing fuel
from flowing into the auger feed system.
CAUSE: Auto-Start Igniter fails to ignite the fuel in the burn pot.
Turn the stove "OFF". Clear the unburned fuel from the burnpot and try again.
Check the pellet quality. Replace if moist, wet, or dirty.
Loss of draft pressure. Make sure that the viewing door is closed and sealed properly. If not,
adjust door catch and/or replace door gaskets. Check that all outside connections are clear
of any obstructions. Check the exhaust system; clean as needed.
Check that the auto-start igniter is not blocked with ash or soot. (The igniter is located
behind the burnpot on the back wall of the firebox.)
Check that the pressure switch connection to the firebox is free of ash or clear of obstructions.
The auto-start igniter gets "red hot" during start-up. If you can not visibly see the igniter
glowing during start-up, then the igniter may need to be replaced or there is a problem with
the electrical control system.
CAUSE: Power outage
Turn off the circuit board and turn it back on.
WITH OPERATING INSTRUCTIONS IN THIS MANUAL.

TROUBLESHOOTING GUIDE

18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F20-571

Table des Matières