OPERATING PROCEDURES
SET UP
Your stapler is fully assembled when you receive it. See the recommended air
system setup below.
Be sure that the couplers are set up so that the air hose is depressurized when
adding or removing components from the system.
Stapler
AIR SOURCE
The FSCN2-1 is designed to operate on clean, dry, compressed air, regulated
at 60-100 psi / 414 to 689 kPa / 4.14 to 6.89 bar. The preferred system would
include a filter, a pressure regulator, and an automatic oiler located as close to
the tool as possible (within 15 feet / 5 meters is ideal). Do not use bottled air or
gases.
Determine if it is necessary to lubricate. All compressed air contains moisture
and other contaminants that can harm the internal components of the tool. An
air line filter will remove most of these and significantly prolong the life of the
tool. If you are using an in-line automatic oiler, check and add oil if necessary.
If an in-line oiler is not available, place 2 drops of oil into the tool's Air Plug (47)
at the beginning of each workday. More than this will be expelled from the tool's
exhaust during firing.
Air Fitting: The FSCN2-1 should be equipped with a 1/4" NPT male 'quick con-
nector'. To prevent accidental cycling even though disconnected, the tool must
always be connected to the air supply in such a way that all air pressure in it is
released when the coupling is disconnected.
CAUTION:
All air line components (including hoses, pipe, connectors, filters, & regulators,
etc.) must be rated for a minimum working pressure of 150 psi / 1034 kPa /
10.3 bar or 150% of the maximum system pressure, whichever is greater.
Disconnect the tool from the air supply before performing maintenance,
clearing a jammed fastener, leaving the work area, moving the tool to another
location, or handing it to another person.
LOADING THE FASTENERS
CAUTION:
Keep the tool pointed away from yourself and others at all times.
Do not load fasteners with safety or trigger depressed.
Always wear approved safety glasses and hearing protection when preparing
or operating this tool.
Never use a tool that leaks air or needs repair.
Be sure the tool is disconnected from the air supply BEFORE loading fasteners
4
All manuals and user guides at all-guides.com
Quick Connector
Air Line
Oiler
Filter
Regulator
Air Supply
!
!