1. Install the drain with a slope of about 10°
so as to drain condensed water easily.
Make sure the drain joint does not leak.
These parts should also be insulated so
as to avoid condensation of the surface
of same.
2. There is a drain outlet on both sides.
Select the desired outlet and insert a cap
on the other side. The clamp must be
used to fasten and isolate the drain out-
let correctly.
3. When received from the factory, the drain
is on the right side of the unit.
Drain insulation
INSULATION
DRAIN
Fig. 1
NOTE: Drain joints must be insulated to
avoid water leaks.
Drain design
1. Install the drain with a 1/50 - 1/100 slope
so as to avoid buckling and curves.
2. When the drain is connected to the unit,
stress on the drain side should be slight,
and the tubing should be located and
fastened near the unit.
3. As a general rule, the drain pipe should
be hard PVC. When connection is made,
insert one end of the PVC tubing in the
drain hole and fasten.
4. When drains are used for different units,
the position of the common tubing
should be at about 100 mm. below each
unit.
Checking drain system
1. Drain system must be checked after in-
stallation.
2. Make sure water flow through the tub-
ing is correct, and the absence of leaks
at the joint.
3. For new constructions, it is advisable to
check prior to furnishing.
12
All manuals and user guides at all-guides.com
Installing wall remote con-
trol unit
1. First, select the location. Remember you
must drill a hole or groove to pass the
cable.
2. The connecting cable between the wall
remote control unit (dimensions: 120 x
120 x 16) and the indoor unit can be
concealed beneath a PVC gutter (Fig.
2); or can be embedded (Fig. 3). Con-
nect the cable to the wall remote control
unit (Fig. 4) and fasten the unit to the
wall.
3. Drill two holes in the wall in correspond-
ence with the rear screws, insert the
wedges and align the holes with the
screws and tighten the latter.
Surface installation
Fig. 2
Embedded installation
Fig. 3
CONNECTOR
RECEIVER
LCD DISPLAY
Fig. 4
GB
NOTE:
1. The distance between the electronic
board and the wall remote control unit
can be over 20 m. (standard distance, 8
m.).
2. The ON/OFF switches (group control)
are reserved for other users of the en-
tire system (this allows each user to turn
the unit on manually, but the system will
not go off until all switches are discon-
nected).

Cable connections

Connecting cables to the ter-
minals
(Fig. 5)
NOTE: Please check the following points
prior to installation.
1. Make sure power supply voltage coin-
cides with the indication on the electronic
board.
2. The energy contracted must be in ac-
cordance with the corresponding needs,
and the power supply cable must have
a section of over 2.5 mm².
3. Wiring should be carried out by quali-
fied personnel. It should include a safety
system with a differential switch having
a 3 mm. separation between contacts.
- Flexible cable.
1. Strip about 10 mm. of cable.
CABLE
2. Remove screws from the connecting
strip.
3. Place a round terminal on the stripped
part of the cable.
4. Insert the screw in the circuit and tighten
the terminals.
CONNECTOR
FLEXIBLE