HYDRA X
3.5

TECHNICAL DATA

Gasoline engine, power
Honda
Fuel Capacity
Max. operating pressure
Max. sound pressure level
Max. size of tip with a spray gun
1-gun
2-gun
3-gun
4-gun
5 gun
6 gun
Max. volume flow
4.0 gal (15.1 l)/min 2.8 gal (10.6 l)/min
Weight
Suction system
Max. viscosity
Dimensions L x W x H
Max. temperature of the coating material
Hydraulic oil filling quantity
Max. tire pressure
* Place of measurement: 1 m distance from unit and 1.60
m above reverberant floor, 120 bar (12 MPa) operating
pressure.
4500 PSI
7250 PSI
389cc, 11.7 Hp,
389cc, 11.7 Hp,
8.7 kW
8.7 kW
1.6 US gal (6.06 l)
1.6 US gal (6.06 l)
4500 PSI
7250 PSI
98 dB (A)*
98 dB (A)*
0.067" – 1.70 mm
0.065" – 1.65 mm
0.041" – 1.04 mm
0.035" – 0.89 mm
0.035" – 0.89 mm
0.028" – 0.71 mm
0.031" – 0.79 mm
0.025" – 0.63 mm
0.029" – 0.73 mm
0.021" – 0.53 mm
0.025" – 0.63 mm
390 lbs (177 kg)
390 lbs (177 kg)
Siphon tube
Siphon tube
65,000 mPa·s
65,000 mPa·s
48" x 32" x 52"
48" x 32" x 52"
109ºF (43° C)
109ºF (43° C)
22.7 l (6.0 gal)
22.7 l (6.0 gal)
0.2 MPa (2 bar, 30
0.2 MPa (2 bar, 30
PSI)
PSI)
OPERATING TEMPERATURE
This equipment will operate correctly in its intended ambient,
at a minimum between +50ºF (10°C) and 104ºF (+40°C).
RELATIVE HUMIDITY
The equipment will operate correctly within an environment
at 50% RH, 104ºF (+40°C). Higher RH may be allowed at lower
temperatures.
Measures shall be taken by the Purchaser to avoid the harmful
effects of occasional condensation.
ALTITUDE
This equipment will operate correctly up to 2100 m above
mean sea level.
Contact your local Honda representative for operating the unit
above 2100m above mean sea level.
TRANSPORTATION AND STORAGE
This equipment will withstand, or has been protected against,
transportation and storage temperatures of -13ºF (-25°C) to
131ºF (+55°C) and for short periods up to 150ºF (+70°C).
Fluid pump should be stored in glycol below 32ºF (0ºC).
It has been packaged to prevent damage from the effects of
normal humidity, vibration and shock.
DESCRIPTION OF UNIT