Télécharger Imprimer la page

Fiap Aqua Active Mini Notice D'emploi page 3

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
FIAP Aqua Active Mini
GB
Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit
prior to using it for the first time. Adhere to the safety information for the
correct and safe use of the unit.
Intended use
The FIAP Aqua Active Mini Set 650 – 3.000 series, in the following text
termed unit, is exclusively intended for pumping normal pond water for
water features and fountains. Ensure that the unit is only operated at a
water temperature of +4°C to +35°C and at a rated voltage coinciding with
the information on the type plate.
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance
with the intended use and in the case of misuse. If used for purposes other
than that intended, our warranty and operating permit will become null and
void.
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive (89/336/EEC) as well
as the low voltage directive (73/23/EEC). The following harmonised
standards apply:
EN 60335-1, EN 60335-2-41, EN 55014-2, EN 61000-3-2, EN 61000-3-3
Safety information
For safety reasons, children and young persons under 16 years of age as well as persons who
cannot recognise possible danger or who are not familiar with these operating instructions, are
not permitted to use the unit!
Please keep these operating instructions in a safe place! Also hand over the operating instructions
when passing the unit on to a new owner. Ensure that all work with this unit is only carried out in
accordance with these instructions.
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly
connected or misused. Only operate the unit if no persons are in the water! Prior to reaching into the
water, always disconnect the power supply to all units used in the water. Compare the electrical values
of the power supply with those on the type plate on the packaging or on the unit itself. Ensure that the
unit is fused for a rated residual current of max. 30 mA via a residual current-operating system. Only
use cables approved for outside use. Do not carry or pull the unit by the connection cable! The power
connection cable of this unit cannot be replaced. If the cable is damaged, the entire unit has to be
disposed of. Electrical installations at garden ponds must meet the international and national
regulations valid for installers. Never open the unit housing or its attendant components, unless this is
explicitly mentioned in the operating instructions. Never carry out technical changes to the unit. Only
use original spare parts and accessories for the unit. Only allow authorised customer service outlets to
perform repairs. Never run the unit without water! Never use the pump for fluids other than water! For
your own safety, consult a qualified electrician when you have questions or encounter problems!
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. 01/2008
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
5
www.fiap.com
FIAP Aqua Active Mini
Assembly and installation
Screw T distributor to the connection socket, screw nozzle tube to the T distributor. Screw nozzle
mounting and the desired water feature nozzle to the nozzle tube. It is possible to connect a hose to
the lateral outlet at the T distributor by means of the reduction element and the stepped hose
connection. Place the unit in the pond horizontally on firm, sludge-free ground and ensure that it is
completely covered with water (at a maximum of 1,3 m below the water level).
Start-up
Attention! Never operate the unit without water flowing through!
The unit switches on automatically when connection to power is established. Align the nozzle tube.
The water feature height and the water flow can be adjusted with a regulator at the lateral outlet at the
T distributor. The power supply must be disconnected to switch off the unit.
Cleaning
Attention! Always disconnect the power supply prior to starting cleaning and maintenance
work!
Unscrew the nozzle tube including T distributor and connection socket. Open strainer casing and
remove pump. Unscrew pump lid and remove impeller. Clean all components using clear water and a
brush. After cleaning the pump, reassemble in the reverse order. Route connection cable such that it
cannot be pinched.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean the unit, check for
damage and store immersed in water in a frost-free environment. Do not immerse the plug!
Wearing parts
The rotor is a wearing part and is, therefore, not covered by our warranty.
Disposal
Dispose of the unit in accordance with the national legal regulations.
Malfunctions
Malfunction
The unit is not operating
No mains voltage
Insufficient delivery rate
Impeller blocked
Strainer casing clogged
Excessive pressure losses in
the hoses
Unit switches off after a short
Water temperature too high
running period
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. 01/2008
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
Cause
Remedy
Check mains voltage
Clean impeller
Clean strainer casing
Reduce hose length and
connecting parts to a minimum,
route hoses as straight as
possible
Note maximum water
temperature of +35°C
www.fiap.com
6

Publicité

loading