Télécharger Imprimer la page

Promax MINIMAX-E Manuel D'utilisation page 5

Masquer les pouces Voir aussi pour MINIMAX-E:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
Advanced Test Products
GENERAL INFORMATION
Before operating the MINIMAX-E recovery unit, read the following:
1. Always isolate large amounts of refrigerant and close off valves after use so if a leak
should develop anywhere in the system the refrigerant does not escape.
2. Storage cylinders sometimes have valves that are not properly seated when
manufactured. Keeping caps on these valves will guard against refrigerant leakage.
3. Always operate the unit on a flat level surface.
4. Your MINIMAX-E has one internal high-pressure shut-off switch. If the pressure
inside the system should go above 38,5 bar (550 psi), the system will automatically
shut itself off.
The 38,5 bar (550 psi) switch does not prevent tank overfill. If your system shuts
off on high pressure and is connected to your tank, you may have overfilled your
tank and created a very dangerous situation! Take immediate measures to relieve
any high pressure and/or tank overfill.
5. WARNING! Never overfill storage tanks. Overfilling may cause tanks to explode.
6. A scale must be used to avoid overfilling the storage tank.
7. Tanks and filters should be designated for one refrigerant only. Before using a tank
previously used for another refrigerant, completely empty the tank, evacuate it,
purge the tank using dry nitrogen, and re-evacuate it.
8. Special care should be taken when recovering from a burned-out system. Use two
high acid capacity filters, in series. Alco type EK-162-F or Sporlan type C-162-F are
recommended.
9. When you have finished recovering from the system, flush your MINIMAX-E with a
small amount of refrigerant oil and a small amount of clean refrigerant to purge off
any foreign substances left in the unit.
10. Always empty refrigerant from the unit into a storage tank; see Self Purge/Auto
Evacuate procedure. Liquid refrigerant left in the condenser may expand, causing
damage to components.