5
Connection diagram (all Centreo range)
- The main power line must have a safety protection in accordance with the rules of the country of use.
- The power supply circuit must be equipped with an omnipolar cutting device with an openning gap of 3 mm minimum. (EN60335-1 standard).
- Switch off the installation during connection. After connection: switch your installation on, check the direction of the operator rotation.
If the direction is not the desired one, disconnect power and invert the brown and black wires.
6
Attaching the shutter (all Centreo range)
CHC M10 ZnBl
JZC10 ZnBl
7
End limits adjustment (all Centreo range)
7.1 - Identifiying the end limits
a - Sliding end limits box cover
b & c - Removable memory rings.
d & e - Rotary adjusting wheels.
f & g - Electric switches.
h - Motor crown.
i - Guiding blades.
7.2 - Adjustment
- Down end limit:
1 - Put electrically the shutter to the DOWN wished position.
2 - Remove the memory ring of the right side (c).
3 - Turn the right adjusting ring (e) in the "-" direction until to activate the switch (g).
- Up end limit:
1 - Put electrically the shutter to the UP wished position. (noise of the blades i)
2 - Move the shutter down up to the floor.
3 - Remove the memory ring of the left side (b).
4 - Turn the left adjusting ring (d) 2 turns in the "-" direction (tip: mark the wheel with a pencil).
- Move the shutter up and down to check the end limits positions. If necessary, turn the adjusting wheels in the "+" direction to increase shutter travel or
in the "-" direction to decrease shutter travel.
8
Use
- Electrically with key switch.
4/4
UNSTABLE SWITCH
a
h
230V - 50Hz
N
L
16A FUSE
PE
f
b
d
x 5
x 1
=
- Manually thanks to the declutching
system.
230V - 50Hz
N
Blue
L1
Brown
Black
L2
PE
Green / yellow
8 mm
30 N.m
±3
g
e
i
1
2,5°
=
2
c
1

Publicité

loading

Ce manuel est également adapté pour: