turned to the minimum setting and without pan stands.
- Warning: The ignition device must not be used for more than 15 seconds. If after this length of time the
burner does not light, or if it goes out again accidentally, wait 1 minute before trying to ignite it again
.
Grids
The panstand grids are designed to make the appliance easy and safe to use. Always check the
panstand grids are properly positioned before using the appliance. Furthermore, always check the
protective rubber feet are all present and correctly positioned.
Grid for small pots or pans (optional - Fig.1A)
This is placed on top of the auxiliary burner grid (the smallest one) when pots or pans of reduced
diameter are used, to avoid unbalancing.
Special "WOK" support grid (optional - Fig.1B)
This is placed on top of the triple crown burner when using a "WOK" (concave bottom pan).
In order to prevent serious malfunction of the burner, never use a wok without this special grid
and never use the wok grid for flat bottomed pans
Choosing the right burner
The symbols stamped on the control panel (fig.2) near the knobs indicate which knob correspond
to which burner. To choose the most suitable burner, take into account the diameter of
the pan as well as the pan capacity (see table).
The diameter of the pan must be proportionate to the burner power in order to ensure high yield.
Pan diameter
RTE 753 SF
Burner
minimum
60 mm
Auxiliary R
reducer)
Auxiliary L
Semi-rapid R
100 mm
Semi-rapid L
100 mm
Triple-crown
200 mm
INSTALLATION INSTRUCTIONS
Important!
-
These instructions are intended for qualified technicians.
-
The appliance must be installed correctly, in compliance with current laws.
-
Before carrying out any operation on the appliance, it must be disconnected from the electric supply.
Fitting the appliance in the worktop
The cooktop may be fitted into any worktop, as long as it is heat resistant (minimum temperature of 90°C)
The dimensions of the hole to be made in the worktop and the minimum distances between rear
and side walls and those above the appliance are shown in figure 4.
Isolation below (fig.6):
-
If the cooktop is installed without an oven below it, a separator panel must be placed between
the bottom of the cooktop and the housing below it, at a minimum distance of 10 mm.
-
If the cooktop is installed over an oven, place a separator panel at a minimum distance of 15mm
and follow the oven manufacturer's instructions, ensuring nonetheless sufficient aeration
Diameter
maximum
140
Auxiliary
(with
mm
Semi-rapid Front
160 mm
Semi-rapid Behind
180 mm
260 mm
Triple-crown
RTF 765 SF
Diameter
Burner
minimum maximum
60 mm
(with
reducer)
160 mm
160 mm
Rapid
200 mm
240 mm
9
RDG 20
Diameter
Burner
minimum maximum
60 mm
140 mm
Auxiliary
(with
reducer)
200 mm
200 mm
Rapid
200 mm
240 mm
260 mm
140 mm
240 mm

Publicité

loading

Ce manuel est également adapté pour:

Rte 755 sfRdg 20