Design and Function / Commissioning / Standby mode
11
12
Level indicator for cooling fluid
13
14
Indicator lights during heating
• This serves to display the state of the heating
Indicator light
Green
Yellow
Red
Flashing red
Indicator lights for cooling and overheating
Indicator light
Green
Flashing green
Yellow
Red
8. Commissioning
• Check the filling level of the cooling fluid and replenish this
if required.
• Connect the induction heater to a socket and switch it on
with the switch on the rear of the induction heater.
• An auto-diagnostic test (self-test) of the induction heater
is automatically started and the cooling circuit undergoes
bleeding. "FIL" flashes on the display during this check.
• If the cooling fluid level is too low in the induction heater, error
message E12 is displayed. Top up the cooling fluid.
• If everything is in order, the system goes into standby mode.
22
VIGOR GmbH
[ +49 (0) 21 91 / 97 95 • \ +49 (0) 21 91 / 97 96 00 • ] info@vigor-equipment.com • ^ vigor-equipment.com
Description
Main switch
Power cable
Production sign
Status
Heating in progress
Warning
– limited heating power –
Heating error – overload –
Heating error – incorrect coil –
Status
Cooling in progress
Only water circuit active, bleeding
Warning – overheating imminent –
Cooling error
– no cooling or trapped hose –
• ; Am Langen Siepen 13-15 • 42857 Remscheid • GERMANY
11
13
9. Standby mode
This mode is the default setting of the induction heater,
allowing you to set the desired power of the heating by turning
the encoder:
• Controlled Power Mode (CP): the indicator light lights up red
. – the user sets the desired power of the heating in % of the
maximum power and the induction heater automatically
adjusts the required parameters so that it retains the set
power.
• Power Mode (CF): the indicator light lights up green
.
– the user sets the desired force of the field in
% of the maximum force and the induction heater
automatically retains the set force of the magnetic field.
12
14