Dimensions
Dry weight without hoses, kg/lb
Weight, with oil but without petrol, kg/lb
Weight, 1/2" x 7.5 m (25 ft) hose, dry, kg/lb
Weight, 1/2" x 7.5 m (25 ft) hose with oil, kg/lb
Length with handle folded, mm/inch
Length with handle extended, mm/inch
Width, mm/inch
Height
Height with hose/tool holder extended
Motor
Nominal engine output, kW (see note 1)
Volume, engine oil, l/fl oz
Volume, fuel tank, litres/gal
Hydraulic system
Hydraulic system, tools
Hydraulic system, power unit
Pump type
Outflow, litres/min/gpm
Setting for the excess flow valve, bar/psi
Nominal hydraulic pressure, bar/psi
Main filter (large), micron
Pump filter (small), micron
Volume of oil tank, litres/gal
Oil type
Oil cooling
Noise emissions (see note 2)
Sound power level, measured dB(A)
Sound power level, guaranteed L
Sound levels (see note 3)
Equivalent sound pressure level at the operator's ear, dB(A)
Electrical system
Types of battery
Fuse
Note 1: The power rating of the engine indicated is the average net output (at specified rpm) of a typical production engine for the
engine model measured to SAE standard J1349/ISO1585. Mass production engines may differ from this value. Actual power
output for the engine installed on the final machine will depend on the operating speed, environmental conditions and other values.
Note 2: Noise emissions in the environment measured as sound power (L
difference between guaranteed and measured sound power is that the guaranteed sound power also includes dispersion in the
measurement result and the variations between different machines of the same model according to Directive 2000/14/EC.
Note 3: Equivalent noise pressure level, according to EN ISO 11203:2009, R=1m, is calculated as the time-weighted energy total
for different noise pressure levels under various operating conditions. Reported data for equivalent noise pressure level for the
machine has a typical statistical dispersion (standard deviation) of 1 dB (A).
18 –
English

TECHNICAL DATA

dB(A)
WA
127/280
135/298
8,5/19
10/22
860/34
1300/51
550/22
740/29
920/36
Briggs & Stratton, V-twin Vanguard 18 hp
10,4/14
1,4/48
7,9/2,1
Valve with open centre
Closed loop
Piston pump with variable displacement
20, 30, 40/5, 8, 10
148/2150
110/1595
25
25
10/2.6
ISO 46
Air-cooled, compressed air
Complies with HTMA cooling requirements
100
101
92
U1 size, 12 volt, cold start value 230
10 A, similar to car fuse, placed by the starter motor
) in conformity with EC directive 2000/14/EC. The