Dear Customer,
Thank you for choosing one of our products. Our brand stands for well-engineered, quality made products; driven by innovation
and safety. Our product range encompasses a wealth of products for health and well-being in the areas of heat, weight, blood
pressure, body temperature, pulse, gentle therapy, massage and air.
Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users
and observe the information they contain.
Best regards,
!
Your Beurer Team
1. Important notes – keep for later use!
1.1 Safety notes:
• The scales must not be used by persons with medical implants (e.g. heart pace-
makers). Otherwise their function could be impaired.
• Do not use during pregnancy.
• Caution! Do not stand on the scale with wet feet and do not step on the scale when its surface is wet –
danger of slipping!
• Batteries are highly dangerous if swallowed. Keep batteries and scale out of reach of small children. If batteries are
swallowed, get medical help immediately.
• Keep children away from packing materials (danger of suffocation).
• Batteries must not be charged or reactivated by other means, taken apart, thrown into a fire or short-circuited.
1.2 General notes:
• Not intended for medical or commercial use.
• Please note that measuring tolerances are possible due to technical reasons because the scale has not been calibrated.
• Ages 10 ... 100 years and height settings from 100 ... 220 cm (3-03"–7-03") can be preset. Load capacity: max. 180 kg (396 lb,
28 st.). Result in steps of 100g (0.2 lb, 0.01st). Measurements of body fat, body water and muscle density in steps of 0.1%.
• Place the scale on a firm level floor; a firm floor covering is required for correct measurement.
• The scale should be cleaned occasionally with a damp cloth. Do not use abrasive detergents and never immerse the scale in
water.
• Protect the scale against hard knocks, moisture, dust, chemicals, major temperature fluctuations and heat sources which are
too close (stove, heating radiators).
• Repairs may only be carried out by customer service or authorized dealers. Before submitting any complaint, first check the
batteries and replace them if necessary.
2. Operation
2.1 Inserting batteries
If present, pull the battery insulating strip off the battery compartment cover or remove the battery's protective film and insert
the battery according to the polarity. If the scale fails to operate, remove the battery completely and insert it again. Your scale
is equipped with a "replace battery" indicator. When the scale is operated with a battery which is too weak, "LO" appears in the
display field and the scale automatically switches off. In this case the battery must be replaced (1 x 3V lithium battery CR2032).
2.2 Basic settings
Insert the batteries/"SET" (3 sec.)
Sequence
Set values
Date
year – month – day
Time
hours – minutes
Measurement unit
KG - LB - ST
2.3 Setting user data
"SET"
User data
Set values
Memory position P
1 to 10
Height cm
100 to 220 cm (3'-03" to 7'-03")
Date of birth Age
year, month, day
Sex
male , female
Degree of activity A
1-5
EnGlIsH
Use the
and
buttons to
select and confirm with "SET".
Use the
to select and confirm with
"SET".
7
and
buttons