Télécharger Imprimer la page

V2 SPA DIMOEL NEW ROTOR Mode D'emploi page 33

Kit pour automatiser portails coulissants jusqu'à 600 kg

Publicité

Les langues disponibles
  • FR

Les langues disponibles

L1
Antenna
L2
Antenna shield
Opening command for a standard connection
L3
device with switch normally open.
Pedestrian opening command for a standard
L4
connection device with switch normally open.
L5
STOP command. N.C. switch
L6
Photocell. N.C. switch
L7
Edge. Switch N.C. or resistive rubber edge
L8
Commands common (-) line
24 VAC power output for photocells and other
L9 - L10
accessories
L10 - L11 Power supply for functional test TX photocell
C1
Motor open
C2
Motor common
C3
Motor close
D1 - D2
Courtesy light timer activation switch
D3 - D4
230V - 40W / 120V - 40W blinker
N
230V / 120V power supply - neutral
L
230V / 120V power supply - phase
J1
NOT USED
ADJUSTMENT OF THE POWER
AND OPERATIONAL TIMES
The power and operating times may be adjusted by means of 3
trimmers located on the control unit:
POWER:
motor power.
WORK:
motor operating time (2 - 120 seconds).
m
PLEASE NOTE: it is recommended that operating times be
set with the slow down function disabled (DIP 5 OFF).
m
WARNING: the adjustment of times has to be made
when the gate is still
PAUSE:
pause time before automatic re-closure
(2 - 150 seconds).
CONTROL UNIT INDICATORS
(LEDS)
The highlighted boxes indicate the state of the LEDs when the
gate is resting.
LED
ON
START
START input closed
IN2
START P. input closed
STOP
STOP input closed
PHOTO
PHOTO input closed
EDGE input closed (edge
not pressed)
EDGE
EDGE input closed
(edge pressed)
Edge NO pressed: 8K2
between EDGE input and
common (-)
Opening limit switch
FCA
closed
FCC
Closing limit switch closed Closing limit switch open
mains
Control unit powered-up
Accessory power supply
overload
overload
-29-
OFF
START input open
START P. input open
STOP input open
PHOTO input open
Standard or optical edge
EDGE input open (edge
pressed)
Resistive rubber edge
EDGE input open
(fault)
Opening limit switch open
Control unit NOT
powered-up
Accessory power supply
within normal operational
limits

Publicité

Chapitres

loading

Produits Connexes pour V2 SPA DIMOEL NEW ROTOR

Ce manuel est également adapté pour:

Dimoel new rotor miniZgs390057Zgs557160