Télécharger Imprimer la page

Installing The Limit Switches; Motor Overriding System - V2 SPA DIMOEL NEW ROTOR Mode D'emploi

Kit pour automatiser portails coulissants jusqu'à 600 kg

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLING THE LIMIT SWITCHES

Install limit switches on the rack and fix them using the screws
provided in the tool kit.
m
ATTENTION: check that the limit switch bracket will
work effectively on the limit switch spring of the motor.
MOTOR OVERRIDING
SYSTEM
In case of a blackout, the gate can be operated directly from the
motor. Insert the key supplied in the lock 1 on the front side of
the motor, perform 1/4 of a turn and open the plastic door
completely.
To restore the automation, simply close the door, rotate the key
in closed position and slide the specially provided plastic cover
onto the lock.
The limit switches are wired for installation with the motor on
the right of the gate opening.
If the motor is installed on the left of the gate opening, it will be
necessary to invert the blue and brown cables on the limit switch
and also the motor connector (C1-C2-C3) on the control unit.
m
WARNING: In case the leaf overruns its final position and
impacts against the safety stroke end (i.e. wrong regulation of
the limit switches),and a manual unclamp would be necessary,
before using the above procedure, you have to replace the leaf
setting away from the safety stroke end using the flat screw on
the main motor shaft 2 with a screwdriver.