1
L1
L2
PS124
I Type
I Technology adopted
I Charge-discharge
voltage
I Current delivered
7,5 A for 3 seconds, on start-up
I Accumulation
1,2 Ah, corresponding to an autonomy of
capacity
approx. 12 hours with automation
or 5 minutes with a charge of 4 A
corresponding to an average of at least
I Complete recharge
time
I Battery lifetime
I Ambient
operating
temperature
I Use in acid,
saline or potentially
explosive
atmospheres
I Assembly and
connections
I Protection rating
I Dimensions
I Weight
WARNINGS:
– The products PS124 - PS224 - PS324 are produced by Nice S.p.a. (TV) I.
- All technical specifications stated herein refer to an ambient temperature of 20°C (± 5°C).
- Nice S.p.a. reserves the right to apply modifications to products at any time when deemed necessary, maintaining the same intended use and functionality.
– Lead battery performance is influenced by the relative conditions of use: temperature, absorbed current, charge status, and age of the battery can cause significant variations to the
original specifications.
10
PS224
EN –
TECHNICAL SPECIFICATIONS OF PRODUCT
PS124
Kit of 24 V batteries complete with battery charger for powering automations for automatic gates and doors
Accumulation of electric energy with hermetically sealed lead batteries (maintenance free)
28 V at maximum charge; 16 V at maximum discharge
(the battery is disconnected automatically when totally discharged)
4 A nominal;
on stand-by
10 manoeuvres
approx. 16 hours
estimated at 4 ÷ 6 years; or over 1000 cycles for discharge level of 30%, over 500 cycles for discharge at 50%,
(battery efficiency is reduced in proportion to a decrease in temperature, at -10°C efficiency is 30%;
the battery lifetime decreases on an increase in temperature; at 40°C lifetime may be reduced to 2 years)
Insertion in specific compartments in control units or gearmotors.
Connection by means of specific cable supplied.
IP 30 (use only inside control unit or gearmotors or other protected environments
104 x 53 x h 143 mm
1,450 g
L1
L2
PS224
in the event of a mains power failure
15 A nominal;
20 A for 0.5 seconds, on start-up
1,2 Ah, corresponding to an autonomy of
approx. 30 hours with automation
on stand-by
or 12 minutes with a charge of 15 A
approx. 20 hours
over 200 cycles for discharge of 100%.
from - 20 to + 50°C
No
162 x 78 x h 297 mm
5,500 g
L2
L1
PS324
PS324
8 A nominal;
10 A for 3 seconds, on start-up
2.2 Ah, corresponding to an autonomy of
approx. 20 hours with automation
on stand-by
or 5 minutes with a charge of 8 A
corresponding to an average of at least
10 manoeuvres
approx. 16 hours
163 x 188 x h 48 mm
2,400 g