Diagramme De Menus & Sous-Menus De L'état Des Systèmes Et De Programmation - Guardian Plus RefPlus RC-L Guide De Démarrage Rapide

Table des Matières

Publicité

Diagramme de menus & sous-menus de l'état des systèmes et de programmation
ÉCRANS D'ÉTATS
DES SYSTÈMES
(STATUS SCREENS)
Status:ON
UN
#1
#2
#3
#4
#1
#2
#3
#4
A) SYSTÈME ON/OFF
B) CONFIGURATION
DE L'UTILISATEUR
(UNIT ON/OFF)
(USER SETUP)
ENTER USER PASSWORD
ENTER USER PASSWORD
0000
0000
TEMPERATURE SETTINGS
UNIT STATUS
UNIT:
ON
Setpoint:
000sec(s)
Main page retn del : 02M
SPÉCIFICATIONS
ENTRÉES ET SORTIES
DU SYSTÈME
DIGITALES
(SYSTEM SPECS)
(DIGITAL INPUTS/OUTPUTS)
SYSTEM SPECIFICATIONS
DIGITAL OUTPUTS
PLAN:01
Cmp1: None
Stages: 4 units
Cmp2:None
Redundancy: 01 unit(s)
Cmp3:None
StagesON RTsf:Auto/1Un
Cmp4:None
Cmp5:None
Cmp6:None
ON:60mns OFF:0020mns
DIGITAL OUTPUTS
LEAD ROTATION
Type:
Cmp7: None
True equalization
Cmp8:None
Def1:None
Def2:None
Def3:None
Def4:None
DIGITAL OUTPUTS
COMMUNICATION SETTINGS
Def5:None
Def6:None
BMS Address:001
Def7:None
Def8:None
Protocol: CAREL Local
G.Al: None
Baudrate:19200 baud
FIELDBUS SETTINGS
Address:001
Protocol:
CarelMaster5 expansion
Baudrate:19200 baud
FIELDBUS 2 SETTINGS
Address:001
Protocol:
Carel Expansion Boards
Baudrate:19200 baud
8
MENUS DE CONFIGURATION
DU CONTRÔLEUR
(CONTROLLER SETUP MENUS)
16 : 47 : 48
2020/05/05
*RT: 008.8
o
c
SP: 06.0
o
c
ROT
STA
2nd
Cmp
4th
OFF
3rd
OFF
1st
Cmp
TEMPERATURE READINGS
Sensor 1 :
006.5
o
c
Sensor 2 :
006.7
o
c
Sensor 3 :
006.6
o
c
Sensor 4 :
006.5
o
c
Average :
006.5
o
c
UNITS RUN HOURS
:
040h
:
041h
:
040h
MENU DE PROGRAMMATION
:
038h
(PROGRAMMING MENU)
C) MENU DE SERVICE
D) CONFIGURATION
DES PARAMÈTRES
(SERVICE MENU)
D'USINE
ENTER SERVICE PASSWORD
ENTER FACTORY PASSWORD
0000
OFFSETS
o
00.0
o
ALARMS LOGGING RESET
c
c
Control temp:
008.8
o
c
06.0
o
SYSTEM SPECIFICATIONS
c
DIGITAL INPUTS/OUTPUTS
TEMPERATURE SETTINGS
Setpoint
diff:
01.0
o
c
Ramp:
1.0
o
/120S
c
Temp monitor del:
0120s
Redundancy band
02.0
o
c
SENSOR SETTINGS
Sensors number: 4
Control by: Average
DEFROST SETTINGS (W)
DEFROST AUTO DISTRIB. (W)
Write defrost:000
Units:0
Unit:0
Type: Disabled
Type:Disabled
Day:
Day:
Start:00:00
Def/day:00
Time:00mins
Time:00mins
No defrost:
00:00-00:00
Action:Set
No defrost:
00:00-00:00
Apply: NO
A:Distribute
Apply:NO
DEFROST SETTINGS (R)
DEFROST AUTO DISTRIB. (R)
Read defrost:000
Units:0
Unit:0
Type: Disabled
Type:Disabled
Day:
Day:
Start:00:00
Def/day:00
Time:00mins
Time:00mins
No defrost:
00:00-00:00
No defrost:
00:00-00:00
SOUS-MENU DE LA CONFIGURATION EN USINE
DÉLAIS
(DELAYS)
DELAYS
ON/OFF:
015secs
Fact. pass enab:
30mins
CARACTÉRISTIQUES/ALARMES
ACTIVÉES/DÉSACTIVÉES
(FEATURES/ALARMS - ENABLE/DISABLE)
ENABLE ALARMS?
Not used
PROGRAMMING MENU
G>VERSION INFO
A>UNIT ON/OFF
B>USER SETUP
E) HISTORIQUE
DES ALARMES
(ALARM HISTORY)
(FACTORY SETUP)
16 : 47 : 48
2020/05/05
005:Redundant unit ON
SetP:
-010.0
o
c
0000
Diff:
02.0
o
c
RedDF:
02.0
o
c
Cmp1
Cmp2
RT: 006.5
o
c
Cmp3
CT: 006.3
o
c
FACTORY SETUP MENU
Index:0
TEMPS DE
FONCTIONNEMENT
RÉINITIALISATION
DES APPAREILS
(FACTORY RESET)
(DEVICES RUN HOURS)
FACTORY RESET
DEVICES RUN HOURS
Are you sure to reset
this device RUN HOURS
This will factory
registry?
reset the unit.
Choose device
Are you sure?
Save each:
Reset
Seconds per hour: 3600
F) HORLOGE
G) VERSION DU
LOGICIEL
(CLOCK)
(VERSION INFO)
CLOCK SETTING
Clock Mode:
24h
17:06:03
2020/09/08
Set new hour 17:06
Set new date 20/09/08
yy/mm/dd
by REFPLUS
RÉINITIALISATION
ÉTAT GÉNÉRAL
DU REGISTRE DES
DES SYSTÈMES
ALARMES
(GENERAL STATUS)
(ALARMS LOG. RESET)
16 : 47 : 48
2020/05/05
ALARMS LOGGING RESET
Status:ON
*RT: 008.8
o
c
CT: 06.0
o
c
Are you sure to reset
UN
ROT
STA
the alarms logging?
#1
2nd
Cmp
#2
4th
OFF
12hour(s)
#3
3rd
OFF
Reset
#4
1st
Cmp
LEAD LAG CONTROLLER
30072010
VERS 1.0
R