I N S TA L L AT I O N
SAFETY WARNINGS
WARNING: THIS WARNING IS AFFIXED TO THE APPLIANCE. THIS APPLIANCE MUST
BE INSTALLED IN ACCORDANCE WITH REGULATIONS IN FORCE AND ONLY
USED IN AN ADEQUATELY VENTILATED AREA. ALWAYS READ THE INSTRUCTIONS
PROVIDED IN FULL BEFORE INSTALLING AND USING THIS APPLIANCE. THIS
APPLIANCE MUST BE INSTALLED BY SPECIALIST GAS SERVICE ENGINEERS.
THIS APPLIANCE IS DESIGNED AND MANUFACTURED FOR COOKING FOOD
ONLY. ANY OTHER USE IS CONSIDERED IMPROPER AND INCORRECT CREATING
HAZARDOUS CONDITIONS. THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR DAMAGE TO THINGS OR INJURIES TO PERSONS CAUSED BY INCORRECT
INSTALLATION AND / OR INCORRECT AND IMPROPER USE.
BEFORE INSTALLING CHECK THAT LOCAL GAS (GAS QUALITY AND PRESSURE)
AND THE APPLIANCE REGULATORS ARE COMPATIBLE WITH THE APPLIANCE.
GAS REGULATING SPECIFICATIONS FOR THIS APPLIANCE ARE PROVIDED ON THE
LABEL AFFIXED TO THE APPLIANCE (OR ON THE SERIAL PLATE).
THIS APPLIANCE IS NOT CONNECTED TO A FUME EXTRACTION FLUE FOR
EXTRACTING PRODUCTS OF COMBUSTION. IT MUST BE INSTALLED AND
CONNECTED CONFORMING TO INSTALLATION REGULATIONS IN FORCE. IT IS OF
UTMOST IMPORTANCE TO RESPECT LEGISLATION REGARDING VENTILATION.
CABINET APERTURE
THE APPLIANCE MUST FITTED AT AN APPROPRIATE AND SAFE DISTANCE FROM
FLAMMABLE MATERIALS.
This oven has a CLASS 3 grading: BUILT-IN APPLIANCE FOR KITCHENS OR WORKTOPS.
MINIMUM DISTANCES FROM WALLS TO BE RESPECTED
Always respect the minimum distances, depending on model, from walls and floor as illustrated in FIG. 1 - PG. 122.
SIZE OF CABINET APERTURE
Cut-out a hole in the cabinet as illustrated in FIG. 2 - PG. 123 size will depend on appliance model.
The cabinet must be appropriately constructed and aligned horizontally with the worktop and with the unit. The cabinet
aperture must be perfectly squared and aligned.
If there are apertures for cabinet ventilation, prevent flammable materials from entering.
INSTALLING THE FLUE
MODELS FO290TD - FO290TS - FO291TD - FO291TS - FO390TD - FO390TS
FO391TD - FO391TS MUST BE DUCTED TO A ROOF MOUNTED FLUE.
ONLY INSTALL THE TYPE OF DUCTING AND FLUE DESCRIBED IN THESE
INSTRUCTIONS WHICH CAN BE SOURCED AT SMEV OR TRUMA RETAILERS.
THE FLUE AND FUME DUCTING MUST BE POSITIONED AT A SAFE DISTANCE
FROM MATERIALS WHICH ARE NOT RESISTANT TO TEMPERATURES OF 120°C.