Insert the pressure hinges into the box (on the
left or right as you wish) and set them using the
provided screws and washers.
Snap the cover into place onto the hinges. Close it and fix it using the
provided screws.
After the adjustments and settings, fix the cover using the provided
screws.
6 Electrical connections
6.1 - CABLE LIST AND MINIMUM THICKNESSES
Connections
Control panel power supply 230V
Motor power supply 24V
flashing lamp
Transmitter photocells
Receiver photocells
Power supply to accessories
Control and safety devices
Antenna connection
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter based on the actual
power draw from the connected devices and according to the CEI EN 60204-1 standards.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw
and distances.
When connecting products that are not specified in this manual, please follow the documentation provided with said products.
Type
Length of cable
of cable
1 < 10 m
3G x 1,5 mm
2
2 x 1 mm
FROR CEI
2
2 x 0,5 mm
20-22
2
2 x 0,5 mm
CEI EN
2
4 x 0,5 mm
50267-2-1
2
2 x 0,5 mm
2
2 x 0,5 mm
RG58
They must slide in order to turn
Length of cable
10 < 20 m
2
2
3G x 2,5 mm
2
2 x 1,5 mm
2
2 x 1 mm
2
2 x 0.5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
max. 10 m
15 mm~
Length of cable
20 < 30 m
2
3G x 4 mm
2
2 x 2,5 mm
2
2 x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 1 mm
2
2 x 0,5 mm