Operating Instructions
GB
PROBLEM
CAUSE
The unit fails to start
Power supply failure
up
Water-full and its icon lighting
Ambient temperature too low or high
The room temperature is lower than the set temperature in
cooling mode.
Bad cooling effects
There is direct sunlight
The doors and windows are open, the room is crowded or there
are other heat sources
Dirty filter
Air inlet or air outlet clogged
High noise level
The unit is being placed at uneven surface.
The compressor does
Initiation of overheat protection
not work
The remote control
Too long distance
does not work
The remote control didn't aim at signal receptor on unit.
The batteries have no electricity
If you are having trouble with your air conditioner, please refer to below trouble shooting. If nothing of the below
works, please contact your retailer for servicing of your air conditioner.
Error Codes
E0
Room temperature sensor failure
E2
Water full tank when cooling
E3
Evaporator temperature sensor failed
18
CAUSE
REMEDY
Connect the unit to a live socket and turn it on
Drain the water stored in the unit.
It is recommended to use this unit between 8-35
Change the set temperature
Close the window curtain
Close the door and window, remove other heat sources
Clean or replace the filter mesh
Remove the obstruction
Put the unit at a flat and firm place (may reduce noise)
Wait until the temperature decrease, the unit will re-start automatically
Bring the remote control close to the air-conditioner and point it to the
signal receptor on the unit.
Replace the batteries
REMEDY
The product must be returned to the dealer for service.
Take off rubber stopper and empty the water.
The product must be returned to the dealer for service.