11. Level
Automatic level display
Low level: the level-control solenoid valve is open
Normal level: the level-control solenoid valve is closed
Fitted with anti-wave system, which is able to stop the solenoid from opening and closing
unexpectedly.
12. Frost function
The frost function is an important protection that your Tcontrol runs on its own. With any setting
(filtering on 1 or on 0 or on T or on A) if the water temperature drops below 3°C your Tcontrol starts
the frost function. AG appears on the display.
This function consists in turning the filtering system on for 3 minutes every hour, day and night. This
procedure allows you to protect the pumps and the hydraulic system and avoid ice from forming
in the pool.
TECHNICAL DATA
Power supply: 230 Vac 50Hz
Maximum draw: 4.5 Kw
Maximum filtering output load: 2.7 Kw
Maximum hydro output load: 1.6 Kw
Protection rating: IP 65
Operational conditions: between -10°C and +40°C
Measurements: 300 x 240 x h140 mm
Weight: 3.5Kg
Material: ABS
Certification: EC
[OPERATION AND MAINTENANCE HANDBOOK
]
[V-1.16]
AQUA spa