Télécharger Imprimer la page

STERWINS 36V Li-2 Mode D'emploi page 16

Publicité

Les langues disponibles

Les langues disponibles

BATTERY CHARGER
Specifications
Charger
Input
Output
Charging procedure
NOTE: The battery is not shipped fully charged. It is
recommended to fully charge before use to ensure that
maximum run time can be achieved. This lithium-ion
battery will not develop a memory and may be charged
at any time.
1 - Plug the charger into an AC power outlet.
2 - Insert the battery pack (1) into the charger (2).
This is a diagnostic charger. The Charger LED Lights (3) will illuminate in specific order to
communicate the current battery status. They are as follows:
Battery is charging
Fully charged
Battery is too warm
(remove for approx. 30 minutes to allow to cool)
No battery present
Defective battery
(remove and replace with new battery if this occurs)
False defect note:
When the battery is inserted into the charger, and the status LED flashes, remove the battery from
the charger for 1 minute, then reinsert. If the status LED indicates normal than the battery pack is
good. If the status LED is still blinking, remove the battery pack and unplug the charger. Wait 1
minute and plug the charger back in and reinsert the battery pack. If the status LED indicates
normal than the battery pack is good. If the status LED is still blinking then the battery pack is
defective and needs to be replaced.
EN
36VC LI-2
100-240V AC 50-60Hz, 1.9A Max
36V DC, 2.0 A
88
2
Red
Red
Red
Green
Red
Orange
Red
Off
Red
Red blinking
1